Service manual

67
FLUSH ON, POWD.SEC
Rinse times for rinsing detergent after the drum has been filled with water.
The time is given in steps of 1 second in the range 0 -255 seconds.
LEVELCOOLDOWN,SCU
Select the level to which the machine should be filled with the cold water
valve if the wash program includes the rapid cooling function.
Thelevelisgivenindivisions(DIV)intherange0-850.
COOL STEP TEMP
Specify the maximum drop in temperature allowed per minute during coo-
ling. During cooling, the temperature will be monitored so that the average
drop in temperature from the starting temperature down to the specified
intermediate temperature does not exceed the given value.
The temperature is given in steps of one degree in the range 0 - 100 °C.
COOL MIDDLE TEMP
Specify the temperature at which the cooling function should stop monito-
ring that the drop in temperature during cooling is not going too fast.
The temperature is given in steps of one degree in the range 0 -100 °C.
DISPLAYSTATIST.SEC.
Indicate using the knob how long the statistics for COINS – HOUR COUN-
TER – PROGRAM COUNTER are to be displayed when the power to the
machine is switched on. The time is given in steps of 1 second in the range
0 -255 seconds.
SHOW.STAT.DOUBLECLI.
Indicate using the knob how long the statistics for COINS – HOUR COUN-
TER– PROGRAM COUNTER are to be displayed following rapidly pressing
the knob twice. The time is given in steps of 1 second in the range 0 -255
seconds
Program unit