Outputs
• Externalpowersupply(e.g.24VDC)for
pumps is to be connected to 9 and 10. If
the internal power supply (from the washing
machine) is to be used, it may be taken from
1 (N) and connected to 9 and from 2 (L) and
connected to 10. The outputs may be loaded
with max 0.5 A.
• Signalsforpumps1-5aretobeconnected
to connections 12 - 16 where:
 12=Detergentsignal1
 13=Detergentsignal2
 14=Detergentsignal3
 15=Detergentsignal4
 16=Detergentsignal5
• Theprogramsheldonthemachinecanbe
foundonthemachine’sdataplate.
3M14* 3F01* 3R01* 3F02* Other programs
Signal 1 Prewash Prewash Prewash Prewash
Signal 2 Main wash Main wash Main wash Main wash Main wash
Signal 3 Rinse agent Rinse agent Rinse agent Rinse agent Rinse agent
Signal 4 Mop last rinse Disinfection Last rinse Main wash
Signal 5 Bleaching agent Bleaching agent Bleaching agent Bleaching agent Bleaching agent
*M=Mop,F=Farm,R=Restaurant
Inputs
• Thesignallevelmaybe5-24VDC/ACor100
-240VAC.At5-24V,thesignalreference
mustbeconnectedto3andat100-240Vto
4.
NB
Do not mix potentials on the inputs.
NB
Connecting excessive voltage (> 24V) to
connection 3 may damage the I/O module.