Next Generation Side by Side and Top Mount Refrigerators January 2003 - June 2003 5995392593 July 2003
TABLE OF CONTENTS Safe Servicing Practices ------------------------------------------------------------------------------------------- 2 Service Data Sheet, Refrigerant Charge & Energy Efficiency Rating Indexes ------------------- 3 - 7 Troubleshooting Guide --------------------------------------------------------------------------------------------- 8 - 12 Appendix A - Service Data Sheets 240379010 --------------------------------------------------------------------------------------------------------- A1
SAFE SERVICING PRACTICES - ALL APPLIANCES To avoid personal injury and/or property damage, it is important that Safe Servicing Practices be observed. The following are some limited examples of safe practices: 1. DO NOT attempt a product repair if you have any doubts as to your ability to complete it in a safe and satisfactory manner. 2. Before servicing or moving an appliance: • Remove the power cord from the electrical outlet, trip the circuit breaker to the OFF position, or remove the fuse.
Model Number FRS23BH5CQ0 FRS23BH5CW0 FRS23BH6CB0 FRS23BH6CS0 FRS23F4CB0 FRS23F4CQ0 FRS23F4CW0 FRS23F5AW7 FRS23H5ASB6 FRS23H5ASB7 FRS23H7CB0 FRS23H7CQ0 FRS23H7CSB0 FRS23H7CW0 FRS23KF5CB0 FRS23KF5CQ0 FRS23KF5CW0 FRS23KF6CB0 FRS23KF6CQ0 FRS23KF6CW0 FRS23KF7AB7 FRS23KF7AQ7 FRS23KF7AW7 FRS23KR4AB7 FRS23KR4AQ7 FRS23KR4AW7 FRS23R4AB7 FRS23R4AQ7 FRS23R4AW9 FRS23R4CB0 FRS23R4CQ0 FRS23R4CW0 FRS23W3AQ7 FRS23W3AW7 FRS26BH5CQ0 FRS26BH5CW0 FRS26BH6CB0 FRS26BH6CS0 FRS26BH6CS1 FRS26BH6CW0 FRS26F4CB0 FRS26F4CQ0 FRS26F4CW0 F
Model Number FRS26HF6BQ2 FRS26HF6BW2 FRS26HF7BB2 FRS26HF7BQ2 FRS26HF7BW2 FRS26KF5CB0 FRS26KF5CQ0 FRS26KF5CW0 FRS26KF6CB0 FRS26KF6CQ0 FRS26KF6CW0 FRS26KF7AB6 FRS26KF7AQ6 FRS26KF7AW6 FRS26KR4AB6 FRS26KR4AQ6 FRS26KR4AW6 FRS26KR4CB0 FRS26KR4CQ0 FRS26KR4CW0 FRS26KW3AB6 FRS26KW3AQ6 FRS26KW3AW6 FRS26R2AQ5 FRS26R2AW5 FRS26R4AB7 FRS26R4AQ7 FRS26R4AW7 FRS26R4CB0 FRS26R4CQ0 FRS26R4CW0 FRS26RBCW0 FRS26W2AW6 FRS26W2BSB3 FRT15B1BW0 FRT15B3AT3 FRT15G5CSB0 FRT15G5CSK0 FRT15HB3AQ3 FRT15HB3AW4 FRT15HB3AZ4 FRT15IB3AW3 FRT15IB
Model Number FRT18G4AZA FRT18G7CW0 FRT18H6CB1 FRT18H6CQ1 FRT18H6CSB0 FRT18H6CSK0 FRT18H6CW1 FRT18H7CW0 FRT18HS6AB1 FRT18HS6AQ8 FRT18HS6AW8 FRT18IB4AQ6 FRT18IG4AT6 FRT18IG4AZ6 FRT18IS6CW0 FRT18KB2CW0 FRT18KG3CW0 FRT18KS5AW8 FRT18KS6CQ0 FRT18KS6CW0 FRT18LR7AQ8 FRT18LR7AW8 FRT18P6CQ0 FRT18P6CW0 FRT18R7CW0 FRT21BH8CB0 FRT21BH8CS0 FRT21BH8CW0 FRT21FG3CQ0 FRT21FG3CW0 FRT21FG4CQ0 FRT21FG4CW0 FRT21FS6CQ0 FRT21FS6CW0 FRT21G3CQ0 FRT21G3CW0 FRT21H7ASB3 FRT21H7ASK2 FRT21H8CB0 FRT21H8CQ0 FRT21H8CSB0 FRT21H8CSK0 FRT21H8C
Model Number FRT21KS6CQ0 FRT21KS6CW0 FRT21LR7AB7 FRT21LR7AW7 FRT21P6CQ0 FRT21P6CSB0 FRT21P6CSK0 FRT21P6CW0 GLHS237ZAB6 GLHS237ZAW6 GLHS237ZCW0 GLHS239ZCB0 GLHS239ZCW0 GLHS267ZAB5 GLHS267ZAQ5 GLHS267ZAW5 GLHS269ZCB0 GLHS269ZCQ0 GLHS269ZCW0 GLHS280ZAB6 GLHS280ZAQ6 GLHS280ZAW6 GLHT184RAQ8 GLHT186TAW6 GLHT186TAW8 GLHT214RAW4 GLHT216TAW3 GLHT216TAW4 GLRS237ZAB7 GLRS237ZAQ7 GLRS237ZAW7 GLRS237ZCB0 GLRS237ZCQ0 GLRS237ZCW0 GLRS264ZAB6 GLRS264ZAQ6 GLRS264ZAW6 GLRS267ZAB6 GLRS267ZAQ6 GLRS267ZAW6 GLRS267ZCB0 GLRS267ZC
Model Number GRT21G3CW0 GRT21R6AQ5 GRT21S6CQ0 GRT21S6CW0 GS18HTZBQ6 GS18HTZBW6 GS18HTZCQ0 GS18HTZCSB0 GS18HTZCSK0 GS18HTZCW0 GS21HTZBB1 GS21HTZBC1 GS21HTZBK2 GS21HTZBQ1 GS21HTZBW1 GS21HTZCW0 GS23HSZBB2 GS23HSZBC3 GS23HSZBQ2 GS23HSZBW2 GS23HSZCB0 GS23HSZCC0 GS23HSZCC1 GS23HSZCQ0 GS23HSZCW0 GS26HSZBB2 GS26HSZBC3 GS26HSZBQ2 GS26HSZBW2 GS26HSZCB0 GS26HSZCC0 GS26HSZCQ0 GS26HSZCW0 PLHS237ZAB6 PLHS237ZCB0 PLHS238ZCB1 PLHS239ZCB0 PLHS267ZAB6 PLHS267ZCB0 PLHS268ZCB1 PLHS269ZCB0 PLHT189CSB0 PLHT189CSK0 PLHT217TAB4 PL
TROUBLESHOOTING GUIDE PROBLEM Compressor will not run. Compressor runs but does not cool. CAUSE No voltage at wall receptacle. Check circuit breaker, fuse or GFCI (Ground Fault Circuit Interruptor - It is not recommended to connect your refrigerator to a GFCI.) Service cord defective or unplugged at wall receptacle. Check service cord. Low voltage causing compressor to cycle on overload. Voltage fluctuation should not exceed ± 10% of 115 vac (104-127) Control thermostat knob in OFF position.
PROBLEM Compressor short cycles. CAUSE SOLUTION Erratic control thermostat. Replace control thermostat. Faulty relay. Replace relay or starter. Restricted air flow over condenser. Ensure air flow is unobstructed over condenser. Low voltage … fluctuation exceeds ± Call qualified electrician. 10% of 115 vac (104-127). Compressor runs too much. Noisy. * Compressor draws excessive watts. Replace compressor. Inoperative condenser fan motor. Replace condenser fan motor.
PROBLEM Freezer compartment too warm. Fig. A Freezer compartment too cold. * CAUSE SOLUTION Inoperative evaporator fan motor. Check wiring and evaporator fan motor. (Check ADC on Side-by-Sides.) Improperly positioned fan blade. Position fan blade properly. See Figure A. Evaporated frosted up. Check defrost system, adjustments, and door gaskets. Inoperative condenser fan motor. (Forced air condenser models only) Replace condenser fan motor.
PROBLEM Refrigerator warm. compartment too Refrigerator compartment too cold. * CAUSE SOLUTION Inoperative evaporator fan motor. Check wiring and evaporator fan motor. (Check ADC on Side-by-Sides.) Improperly positioned fan blade. Position fan blade properly. See page 10, Figure A. Evaporated frosted up. Check defrost system, adjustments, and door gaskets. Refrigerator compartment overloaded – poor air circulation. Advise customer. Low room temperature.
PROBLEM Refrigerator compartment too cold. (Continued) CAUSE SOLUTION Inoperative cold control. Replace cold control. Refrigerator compartment inlet air duct loose or restricted. Door is loose. Re-install air duct or remove obstruction from air duct. Adjust door. Diffuser (foam block) in top of food compartment is broken. (Foam blocked located in control housing for models with Service Data Sheet numbers 24038960010 and 240379001-10.) Replace diffuser.
PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run Capacitor SERVICE DATA SHEET 65°F (18°C) Ambient 90°F (32°C) Ambient 25 to 35% 45 to 55% 2° to 8°F -17° to -13°C 0° to 5°F -18° to -15°C Refrigerature Temperature 35° to 40°F 2° to 4°C 35° to 40°F 2° to 4°C Low Side Pressure (cut-in) 8 to 16 psig 55 to 110 kPa 8 to 16 psig 55 to 110 kPa Low Side Pressure (cut-out) 1 to 4 psig 7 to 28 kPa 1 to 4 psig 7 to 28 kPa 110 to 120 psig 758 to 827 kPa 150 to 1
Pictorial Schematic Ladder Schematic A-2 Compressor Wiring SERVICE PARTS Compressor Kit * Starter/PTC * Run Capacitor * Temperature Control Timer (if applicable) ADC (if applicable) Defrost Heater Kit Defrost Thermostat Kit Evaporator Fan Motor Condenser Fan Motor 15 & 17 CUBIC FOOT STATIC DYNAMIC E-STAR 5303918264 5303918264 5303918280 218721120 218721120 218721119 218909901 218909901 218909901 5304421256 5304421256 5304421256 215846606 215846606 N/A N/A N/A 240545401 5303918203 5303918203 5303918203
PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run/Star t Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient 32 to 40% 55 to 65% 0° to 4°F -18° to -16°C -1° to 3°F -18° to -16°C Refrigerator Temperature 34° to 39°F 1° to 4°C 34° to 39°F 1° to 4°C Low Side Pressure (cut-in) 5 to 12 psig 34 to 83 kPa 5 to 12 psig 34 to 83 kPa Low Side Pressure (cut-out) -2 to 2 psig -14 to 14 kPa -2 to 2 psig -14 to 14 kPa 90 to 115 psig 621 to 793 kPa 130 to 155 psig 89
Pictorial Schematic Ladder Schematic A-4 Electro-Mechanical Dispenser Electronic Dispenser Compressor Wiring SERVICE PARTS Compressor Kit * Starter/PTC * Run Capacitor * Temp. Control-Refr Temp.
PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run/Star t Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient 32 to 40% 55 to 65% 0° to 4°F -18° to -16°C -1° to 3°F -18° to -16°C Refrigerator Temperature 34° to 39°F 1° to 4°C 34° to 39°F 1° to 4°C Low Side Pressure (cut-in) 5 to 12 psig 34 to 83 kPa 5 to 12 psig 34 to 83 kPa Low Side Pressure (cut-out) -2 to 2 psig -14 to 14 kPa -2 to 2 psig -14 to 14 kPa 90 to 115 psig 621 to 793 kPa 130 to 155 psig 89
A-6 SERVICE PARTS Compressor Kit * Starter/PTC * Run Capacitor * Temp. Control-Refr Temp.
PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run/Star t Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient 32 to 40% 55 to 65% 0° to 4°F -18° to -16°C -1° to 3°F -18° to -16°C Refrigerator Temperature 34° to 39°F 1° to 4°C 34° to 39°F 1° to 4°C Low Side Pressure (cut-in) 5 to 12 psig 34 to 83 kPa 5 to 12 psig 34 to 83 kPa Low Side Pressure (cut-out) -2 to 2 psig -14 to 14 kPa -2 to 2 psig -14 to 14 kPa 90 to 115 psig 621 to 793 kPa 130 to 155 psig 89
240593801 A-8 SERVICE PARTS Compressor Kit * Starter/PTC * Run Capacitor * Temp. Control-Refr Temp.