User`s manual

GLOBAL SETTINGS
73
It is possible to route some tracks to the main outputs and others to A or B. This is
probably not very useful, as the tracks routed to A or B will appear as non-
effected tracks hard panned to either left or right. If you use A and/or B as individ-
ual outputs, you probably do not want to use the MAIN A+B stereo out at all.
TRIG
Machinedrum SPS-1 MKII/SPS-1UW MKII allows the two audio inputs to be used for con-
n
ecting external drum pads. The trig system is prepared for standard piezo elements as
used by most pads and require no amplification before being handled by the Machinedrum.
1. Select the TRIG row in the GLOBAL EDIT menu. Move the focus to IN A by pressing the
[ENTER/YES] key.
2. Press [ENTER/YES]. This will open the trig setting menu for the external input A.
GATE sets the input gate sensitivity. A low value makes the trig more sensitive.
SENS sets the sensitivity of the inputs. The higher the sensitivity the higher the reaction to
weak signals.
VMIN and VMAX sets the minimum and maximum velocity mapping. This controls the
dynamic range of the connected trig pads.
DEST defines which track sound will be trigged by the incoming signal.