User's Manual Part 2

MEGAM.O.L.E.® Help System Guide 188
5.4.4.4. Target 10-OK
Target 10-OK is a simple yet powerful way to achieve the pursuit of the perfect profile.
The user specifies requirements for the profile initial slope, soak, TAL (time above
liquidous), peak parameter and the channels that these requirements are to be applied.
Then the software automatically calculates a single go/no-go number.
Target 10-OK feature allows the user to answer the following questions:
1) How do I specify a good profile?
Answer: Based on the selected process specification and specification limits, the
user can set the four process parameters (Initial slope, Soak, TAL & Peak).
2) How do I know I have a good profile?
Answer: Based on the specified settings, the active individual parameter
indicators (Slope, Soak, TAL & Peak) display the normalized values. Once
Target 10-OK numbers are calculated, they reduce the evaluation of the
displayed data run profile to a single number. This number appears in a three
state (Red-Green-Yellow) indicator with the worst condition number appearing in
the Final Indicator symbol.
A score of less than 0.0 is bad, 0.0-5.0 is good, 5.1-9.9 better and 10.0 being the
perfect score.
3) How can I improve the profile?
Answer: Using the Prediction Tool, the user can change zone temperature
values or the conveyor speed and adjust the outcome toward a perfect 10.0.