User Manual Part 1

CHAPTER 3
PROGRAMMING
ESTEEM FEATURES
Revised: 15 Oct 03 3-3 EST P/N AA104
AUTO CONNECT
The Auto Connect feature allows the user to program the ESTeem to perform a CONNECT to another ESTeem when data is sent
to the RS-232C communications port.
To enable this feature perform the following from the COMMAND MODE:
SETCON (1-255) = Address of destination ESTeem.
Remember, you can use the Repeater routing (r1,r2,r3,da) or put the ESTeem in Global (address 255). SETCON is the set connect
command.
SA SAVE command. This will save the SETC variable to the non-volatile memory so that it will not be lost when the
ESTeem is RESET.
Bit 2 (on/off) = On. Bit 2 is located on the RS-232C SETUP SWITCH on the front of the ESTeem. The ESTeem must be
RESET after the Bit has been changed to be read by the ESTeem CPU.
RESET ESTeem RESET is located on the front panel OFF/ON switch. The T/E light on the front panel of the ESTeem should
now flash at a two times per second rate.