User Manual Part 1
CHAPTER 3
PROGRAMMING
ESTEEM FEATURES
Revised: 15 Oct 03 3-7 EST P/N AA104
USING THE INFRARED COMMUNICATIONS PORT
The infrared (IR) communications port will allow you to
program and interrogate the ESTeem without
disconnecting the serial cable from the back of the
modem. The IR port is located on the front panel of the
ESTeem, above the T/E light.
To communicate from a computer to the ESTeem through
the IR port you will need a copy of the ESTeem Utilities
(Version 4.0 or higher) and an ESTeem IR Communication
Dongle (ESTeem P/N AA300).
Connect the dongle directly to the serial port of the
computer. The dongle requires initialization from the
ESTeem Utilities. From the Terminal Emulation screen
press the F3 function key to initialize the dongle. If the
modem is not in the COMMAND mode, press CTRL-C to
display the CMD: prompt.
Note: With Switch 2 (RS-232 Setup) in the On position the ESTeem defaults the IR port to the command mode.
The IR dongle has a range of approximately three feet, directly in front of the port. The dongle is powered by the serial port and
requires no additional power sources.
Note: Only one of the three communications ports (RS-232/422/485 connector, IR port or Remote Programming) can be in
the Command mode at a time. When either the IR or the Phone port switch to converse mode, the RS-232/422/485
port is blocked from receiving any data.
ANTE
NNA
S/N:
T/E
TX
RX
PWR
IR
Port
Phone
Model 192S
Antenna
12 VDC
RESET
Infrared Communications Port for
Remote Programming and Diagnostics
Without Interruption Of The Wireless
Radio Area Network
IR Communications Dongal
(EST p/n AA300)
3 ft. Range
RE
SET
Figure 1: Using The IR Port