User Manual Part 1
CHAPTER 4
ESTEEM
APPLICATION PROGRAMS
Revised: 8 Oct 03 4-3 EST P/N AA104
INTERACTIVE TERMINAL APPLICATION
This program is used to connect a mainframe to a remote terminal. This setup is a typical point to point configuration with the
AUTO-CONNECT feature enabled.
Perform the following prior to programming the ESTeem(s) to initialize the unit to factory default settings:
1. Turn Bit 2 OFF on the RS-232C Setup Switch.
2. Reset the ESTeem.
3. TYPE FA <Enter>. Please note the characters my not be echoed by the crt.
ESTeem At Mainframe ESTeem At Terminal
-------------------------- ------------------------
ADD xxx ADD yyy
SETC yyy SETC xxx
TERMC ON TERMC ON
TERMT 10 TERMT 10
XSF OFF XSF OFF
XHF ON * XHF ON *
DISACK ON * DISACK ON *
TRANS ON TRANS ON
SAVE SAVE
Bit 2 ON Bit 2 ON (RS-232 Switch)
RESET ESTeem RESET ESTeem
Notes:
• Turn DISACK ON only if you want to defeat the acknowledge packet.
• Only hardware flow control can be used in this mode.
• xxx and yyy represent an ESTeem address which is user definable from 1 to 254.
PROGRAMMABLE LOGIC CONTROLLERS
EST has available complete Engineering Reports for each PLC manufacturer make which will be provided at no charge by calling
EST Customer Support on 509-735-9092. All Engineering Reports are also available on the ESTeem Utility Resource Disk (EST
P/N AA109) in Adobe™ PDF format.