User Manual Part 1

CHAPTER 1
STARTING OUT
Revised: 15 Oct 03 1-5 EST P/N AA104
Saving A Program
A program is saved by typing in the SAVE command at the CMD: prompt. The programming variables that have been changed
will be written to the non-volatile memory. The programming parameters will be loaded each time the modem is powered up or
reset.
Restoring Factory Defaults
The ESTeem has a very simple procedure to restore the program variables in the unit to the factory default setting. When the
FA<Enter> command is entered from the command mode the ESTeem will be configured from a variable table located in its
EPROM. It is a good practice to restore the ESTeem to a factory defaults before any programming of the unit.
To ensure the modem is in the COMMAND MODE set it back to the factory default by performing the following:
1. Set both switches (#1&2) on the RS-232 setup switches to the OFF position.
2. Reset the ESTeem.
3. Verify the computer's Comm port is configured for 19,200,N,8,1.
4. Type FA<Enter> and the ESTeem welcome message should be displayed. The characters may not be echoed on the screen.
5. Type SA<Enter> to save the factory default table.