User Manual Part 2

APPENDIX C
ESTeem MESSAGE TABLES
Revised: 8 Oct 03 APX C-1 EST P/N AA104
ESTeem Command Error Messages
Listed below are the ESTeem Command Error Messages and their definitions. To receive these messages, TYPSYSTEM must be
ON (See Appendix D, Definitions). All System Status Message have a bell (O7H or CTRL G) preceding the message except
when Messform is ON. If MESSFORM = OFF Line A will be displayed. If MESSFORM = ON Line B will be displayed.
1. A "TOO MANY CHARACTERS FOR COMMAND"
B EMO1
This message will be displayed if more than the allocated
number of characters are typed for a command. This is
because some commands are truncated at a length of 8
characters.
2. A "AMBIGUOUS COMMAND"
B EMO2
This is the case of not enough characters being entered
to uniquely identify a command.
3. A "INVALID ARGUMENT"
B EM03
This is displayed when a non valid value is given to a
Command. Example; a value of O cannot be given to
FRACK because the only valid values are 1-255.