User Manual Part 2
APPENDIX D
SOFTWARE COMMANDS
Revised: 13 Sep 05 APX D- 9 EST P/N AA104
REMprog (on/off)
This command will disable the ESTeem from being remotely programmed by any another ESTeem.
ON: Enabled.
OFF: Disabled.
Factory default = ON.
RESet
The software reset command for the ESTeem. The execution of this command resets the internal electronics in the ESTeem.
RESTore
The restore command. The execution of this command restores the ESTeem command variables and switches configurations
stored in nonvolatile memory.
RETry (1-255)
The retry command number. This is the number specifying the number of retries, retransmission of frames, that are not
acknowledged. Frames are retransmitted RETRY times before operation is aborted. Factory default = 6.
RFcycles
This command defines the number of cycles the ESTeem will transmit when programmed with the RADIO COMMAND.
Factory default = 10.
RFWait (1-255)
This command command defines the time in milliseconds the receiver waits afer a carrier detect before starting the acquire
sequence. This value is optimized at the factory for the specific product and should not be changed.
ROUTe (l#,r1,r2,r3,)
The ROUTE sets up the route table in the ESTeem.
l # = User defined route number. Route numbers 1 to 16 may be used.
r1 = Address of first repeater. Address numbers from 1 to 254 may be used.
r2 = Address of second repeater. Address numbers from 1 to 254 may be used.
r3 = Address of third repeater. Address numbers from 1 to 254 may be used.
Note: See APPENDRU Command.
Factory default = 0.
RXData (1-255)
This command defines the time (milliseconds) the receiver waits after a carrier detect before starting the receive sequence. This
value is optimized at the factory and should not be changed.
Factory default = 1.