User Manual Part 2
APPENDIX D
SOFTWARE COMMANDS
Revised: 13 Sep 05 APX D- 10 EST P/N AA104
RXEnd (1-255)
This command defines the time (milliseconds) to wait after the last character is received before reinitializing the receiver.
Factory default = 1.
RXSIGNAL (on/off)
This command enables the signal to noise ratio meter output. Output level varies from 0 to 248 (248 being the highest reading).
ON: Enabled.
OFF: Disabled.
Factory default = OFF.
SAve
The save command. The execution of this command stores the current command values and switches.
Note: Please wait approximately two seconds after executing the SAVE command before turning off power to the ESTeem.
SECURITY (off or 1- 100000)
The security command disables programming the ESTeem.
1 to 100000 This feature is enabled when you enter a number from 1 to 100000. When enabled the ESTeem will return a
Security ON message. To disable security enter SECURity xxxxxx.
xxxxxx = your predefined security number. When disabled the ESTeem will return a Security Off message.
OFF Security disabled.
Factory default = OFF.
SENDDel (0 to 65535)
This command sets the time to wait before sending back the contents of the transmit buffer when a global ENQ is received and
POLL Mode is enabled. This allows for several polled ESTeems to respond back at different times keeping the transmissions
from colliding. Reference Polled Command.
SENDPACK (0-255)
Send packet (SENDPACK) command. The value specifies an ASCII character used to signal when to send the packet. If set to a
value of 255 the command is disabled. The factory default value is 13 (Return).
SEL/A1 (1-255)
The SEL/A1 command sets the transceiver for a specific frequency.
SEL/N1 (1-56635)
The SEL/A1 command sets the transceiver for a specific frequency.
SEL/N2 (1-999)
The SEL/N2 command sets the transceiver for a specific frequency.
SETCon (r1,r2,r3,da)
This command defines the destination address for the ESTeem to perform a connect using the Auto Connect feature. This
function supports a direct connect or a connect through a maximum of three repeaters.
r1 = ESTeem address (1 to 254) of repeater 1.
r2 = ESTeem address (1 to 254) of repeater 2.
r3 = ESTeem address (1 to 254) of repeater 3.
da = Destination address (1 to 254).