User's Manual

APPENDIX F
TROUBLESHOOTING
Revised: 14 Jun 06 APX F-10 EST P/N AA107G
is the WLAN MAC address is not configured in both 195Eg’s repeater tables. If only one side is configured, everything will
appear to be correct but no communication will function.
EtherStation
How do I access the Model 195Eg web page in EtherStation Mode? The Model 195Eg does not have an active web browser
when configured in EtherStation mode. You must access the ESTeem with the ESTeem Discovery Program or through the RS-
232 port after configuration in this mode. To monitor the link status, you can use the EtherStation Status program.
What IP address do I configure the ESTeem in EtherStation mode? – The Model 192E will not have an IP address in EtherStation
mode.
I can not link my device into the wireless network – Verify that the MAC address of the device is exactly the same as configured
in the Model 195Eg. The MAC address must have colons between the values.
Can I connect my Model 195Eg in EtherStation mode to a HUB or Ethernet Switch? – No. The modem must be connected
directly to the Ethernet device for which it is programmed. In EtherStation mode the Model 195Eg can only service ONE
Ethernet device.