Weight: Unit only: 22 oz., One probe and 6 foot cable: 3.5 oz., One Probe and 20 foot cable: 7 oz.
Environmental: Meets TSO C43a
Power Requirements: 10.5 to 30 Volts, 3/10 Amp.
Display: Plasma (viewable in direct sunlight). Display dims for night operation.
Accuracy: 1/2% in accordance with TSO C43a.
Power-up Test: Flashes all bars, segments and nomenclature.
Probes: Type K, Ungrounded (for improved accuracy, stability and reliability).
Extension Cables: Type K, any length or size. Non-Temp cables are tin/copper.
Channels: Maximum of 16 Channels.
EGT and CHT Analyzer Channels: 1 to 7, programmable from front panel (left channels for EGTs and right
channels for CHTs).
EGT Bar Resolution: 1 to 104°F per Bar, programmable from front panel.
CHT Bar Resolution: 33°F per Bar.
Lean Operating Mode:
A. Activated after 10°F rise in hottest EGT.
B. Peak detected when 5°F decrease in any EGT or TIT.
Scan Rate: Programmable from 1 to 9 second per channel.