Installation guide
6 
3.4.1. Detectors 
The CommPact supports 33 security zones. Only one detector can be registered to each 
zone. Zones 1-32 are intended for wireless detectors by default. Zone 33 is an on-board 
hardwire zone (can be configured as NO, NC or EOL). 
Step 1: Register a detector
1.  Go to the main menu and select [9]>[1]>[1] (Programming> Devices > Zones) 
2.  Using the arrow keys, select a specific zone and press 
'√'. The system initiates 
Registration mode. 
3.  Send two transmissions from the detector. A confirmation sound is heard after 
each successful signal (chime sound). After two successful transmissions a 
confirmation beep is heard. 
Sending the transmissions can be done in several ways, as summarized in 
Table 2. 
Device 
Device Model 
Number 
Sending Transmissions 
PIR Detectors 
EL-2645 
EL-2645PI 
Apply battery power. Place the mode 
jumper over pins 2 and 3 (Radio Mode); 
the LED flashes. 
OR 
Depress the tamper switch twice, in rapid 
succession. 
Magnetic Contact  EL-2601 
When you apply battery power and the 
tamper switch is open, the device enters 
test mode in which a transmission is sent 
every few seconds. You can terminate the 
test mode by closing the tamper switch. 
Flood Sensor  EL-2661 
Universal 
Transmitter 
EL-2602 
Glass break  EL-2606 
Smoke Detector  EL-2603 
Press the test button. Verify that the 
transmission LED is lit momentarily.  Wait 
five seconds and press the test button 
again. 
Table 2: Transmission sending 
4.  After the detector is successfully registered the display shows: 'Save?' 
Press 
'√' to confirm and continue entering other parameters for the chosen 
device (see section below) or press X to go back and enroll additional zones. 
Step 2: Set detector's parameters
1.  Go to the main menu and select [9]>[1]>[1] (Programming > Devices > Zones) 
2.  Using the arrow keys select a specific zone and press 
'√'. 