Installation guide
8 
In addition the menu shows the detectors status using the abbreviations in Table 5. 
Table 5: Abbreviations 
3.4.2. Keyfobs 
The CommPact Control System supports up to 19 keyfobs. 
Step 1: Register a keyfob 
1.  Go to the main menu, select [9]>[1]>[2] (Programming > Devices > Keyfobs) 
2.  Using the arrow keys select a specific keyfob and press '√'. The system initiates 
Registration mode. 
3.  Press a button on the keyfob, assuring the keyfob’s LED lights up when the 
button is pressed. 
4.  Press the same button again. 
5.  When 'Save?' appears on the Control System’s LCD display, press '√'. 
Step 2: Set the keyfob's parameters
1.  Go to the main menu, select [9]>[1]>[2] (Programming > Devices > Keyfobs) 
2.  Using the arrow keys select a specific keyfob and press '√'. 
3.  Set the parameters for each keyfob according to Table 6. 
Quick 
Key 
Option Name  Description and Notes 
9>1>2>2  Type  Controlled or non-controlled. A controlled keyfob causes 
the system to send set/unset event messages to the central 
station. Non-controlled keyfobs never send set messages 
and send a unset message only if the system is disarmed 
after an alarm occurrence 
9>1>2>3  Descriptor  Descriptors help identify the device when you operate 
and program the system. Use the 
 /   key to insert a 
space 
9>1>2>4  KF1 PGM  Defines whether the keyfob can control the PGM with the  
 /   button. 
9>1>2>5  Delete  Delete a keyfob 
Table 6: Keyfob parameters 
Item  Description… Item  Description… 
OK  The transmitter is 
functioning correctly 
OS  The transmitter is not 
synchronized 
TA  Tamper condition  NA  The transmitter is inactive 
BT  Battery low     