Installation manual
-12- 
ARMED: The Armed LED lights to indicate the system is armed or in programming 
mode and flashes during the exit delay. 
POWER: The Power LED lights up when both AC & battery power are OK, flashes 
when the battery is low & AC power is OK, and goes out in the event of AC failure. 
3.3: Command Codes 
To execute a command, press the ‘4‘ button followed by the corresponding command 
number. In certain cases, you are required to enter a valid user code. 
The following is a summary of the command codes used in system operation. 
40 
Quick Arm 
45 + (User Code 1) 
Program User Codes 
41 + (User Code) 
Bypass Mode 
46 
Zone Chime 
42 
Emergency/ 
Trouble Event Log
47 + (Installer Code) 
Programming Mode 
43 
Zone Alarm 
Event Log 
48 + (User Code) 
Forced Arming 
441 
442 + (User Code 1) 
Bell/LED Test 
Walk Test 
49 + (User Code) 
ENTER 1 + (User Code 1)
Stay Arming 
Stop Communications 
3.4: Arming/Disarming 
The following section explains the various arming and disarming methods. 
Arming 
When all zones are secured, you can arm the system normally. Arming the system sends a 
message to the central station identifying which user performed the operation. 
To arm the system: 
1.  Check that all zones are closed; the Ready LED lights up to indicate that the 
system is ready to be armed. 
2.  Enter a valid user code; the keypad beeps until the end of the exit delay. 
Forced Arming 
Forced arming enables you to arm the system with open zones. Electronics Line 3000 
recommends waiting until all of the zones are secured and the system can be armed 
normally. 
Note: If zones are still not secured after the exit delay has ended, an alarm will be generated. 
To force arm the system: 
1. Press 4, 8. 
2.  Enter a valid user code; the keypad beeps until the end of the exit delay. 
Quick Arming 
This feature enables you to arm the system without a valid user code. Quick arming the 
system transmits an “Armed by User 1” message to the central station. 
To “Quick” arm the system: 
1.  Check that all zones are closed; the Ready LED lights up to indicate that the 
system is ready to be armed. 
2. Press 4, 0; the keypad beeps until the end of the exit delay. 