User's Manual

TraceableLIVE
WiFi
DATALOGGING
BAROMETRIC
PRESSURE
HYGROMETER
THERMOMETER
WITH REMOTE
NOTIFICATION
INSTRUCTIONS
®
Make sure Network ID, password, and security type
are selected right, and try to congure the network
again.
NOTE: The device date/time is automatically
synchronized to the mobile phone or laptop once the
setup webpage is shown.
NOTE: Make sure Network ID and password are correct;
otherwise the device will wait to connect to the router
until timeout, and then “Err” is shown on LCD.
CONFIGURE WiFi NETWORK: WPS PROVISIONING
Press WiFi button to enable WiFi function. If it is rst
time enabled, WiFi symbol ashes.
Press and hold WiFi button for 3s till the device
displays “AP”;
Press UP or DOWN button to scroll to WPS. “UPS” is
displayed on LCD.
Press and release WiFi button, the device displays
“AP UAIT”.
Wait until LCD displays “UPS rEAdy” (WPS ready).
Press WPS button on the router that the device
is intended to connect to. Please refer to router’s
manual for WPS function.
If network is congured successfully, the device
reboots, and ready to use.
NOTE: The router has to support WPS, and WPS
function has to be enabled. The device supports only
PUSH BUTTON Method. Pin Code Method is NOT
supported.
NOTE: Using WPS provisioning will not update the
device’s date/time.
HOW TO CONFIGURE WiFi NETWORK:
SMARTCONFIG PROVISIONING
Press WiFi button to enable WiFi function. If it is rst
time enabled, WiFi symbol ashes;
Press and hold WiFi button for 3s till the device
displays “AP”;
Press UP or DOWN button to scroll to SmartCong.
“SnArT” is displayed on LCD;
Press and release WiFi button, the device displays
“AP UAIT”;
Wait till LCD displays “SnArT rEAdy” (SMART ready);
On TI’s WiFi Starter App, enter Network ID and
password, and press Start button.
If network is congured successfully, the device
reboots, and ready to use.
NOTE: this method requires user to install TI WiFi
Starter app for iOS or Android on mobile devices.
NOTE: Using SmartCong provisioning will not update
the device’s date/time.
DATA MEMORY
1. Device is capable of storing 7 days of data if 15
minute logging interval is set.
2. If data transmission fails, data will be stored in data
memory. Stored data will be transmitted automatically
on next successful transmission.
WARRANTY, SERVICE, OR RECALIBRATION
For warranty, service, or recalibration, contact:
CONTROL COMPANY
12554 Old Galveston Rd. Suite B230
Webster, Texas 77598 USA
Ph. 281 482-1714 • Fax 281 482-9448
E-mail sales@control3.com
www.traceable.com
Control Company is ISO 9001:2008 Quality-Certi-
ed by DNV and ISO/IEC 17025:2005 accredited
as a Calibration Laboratory by A2LA.
Control Company Cat. No. 6529
Traceable
®
and TraceableLIVE
®
are registered trademarks
of Control Company.
©2017 Control Company. 92-6529-00 Rev. 3 041117
3. If WiFi network has been congured, and WiFi
connection is lost, data will be stored in data memory
at user-dened logging interval.
4. If WiFi network has not been congured, data will not
be stored in data memory.
5. Stored data in data memory cannot be cleared by
user. It can only be cleared by a successful data
transmission.
ALARM REPOST
If an alarm triggers and stays in triggered condition,
after a user-dened period, the device will
repost alarm to cloud server even if a user has
acknowledged the alarm.
Alarm Repost feature is disabled by default, to enable
see DEVICE SETUP.
Alarm Repost period is set to 60 min by default, a
user can change the interval between 5 minutes to 8
hours (5 minute increments).
ALTITUDE COMPENSATION
Device compensates altitude from sea level.
Compensation ranges: –100 to 2,500 meters.
If wi- enabled, altitude can only be set through
TraceableLIVE
®
cloud server.
DISPLAY MESSAGES
If no buttons are pressed and - - -.- - appears on the
display, this indicates that the temperature being mea-
sured is outside of the temperature range of the unit, or
that the probe is disconnected or damaged.
BENCH STAND
The unit is supplied with a bench stand located on the
back. To use the bench stand, locate the small opening
at the bottom back of the unit. Place your ngernail into
the opening and ip the stand out. To close the stand,
simply snap it shut.
LOW BATTERY POWER INDICATOR
Unit is supplied with 4 AAA alkaline batteries. If the bat-
tery power drops to 20% or lower a low battery symbol
will appear on device display, and an alert will be
sent via TraceableLIVE.
ALL OPERATIONAL DIFFICULTIES
If this thermometer does not function properly for any
reason, please replace the battery with a new high-quality
battery (see “Battery Replacement” section). Low battery
power can occasionally cause any number of “apparent”
operational difculties. Replacing the battery with a new
fresh battery will solve most difculties. If the voltage of
the battery becomes low °C and °F symbols will ash.
BATTERY REPLACEMENT
Erratic readings, a faint display, or no display are all
indications that the battery must be replaced. Slide the
battery cover toward the end of the unit. Remove the
exhausted battery and replace with AAA alkaline battery.
Replace the battery cover.
REGULATORY INFORMATION
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful
interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will
not occur in a particular installation. If this equipment
does cause harmful interference to radio or television
reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV
technician for help.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired
operation.
Hereby, Control Company, declares that this digital
thermometer is in compliance with the essential
requirements and other relevant provisions of Directive
1999/5/EC.
This device complies with Industry Canada licence-
exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause
interference, and (2) this device must accept any
interference, including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie
Canada applicables aux appareils radio exempts de
licence. L’exploitation est autorisée aux deux conditions
suivantes : (1) l’appareil ne doit pas produire de
brouillage, et (2) l’utilisateur de l’appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage
est susceptible d’en compromettre le fonctionnement.
NOTE: THE GRANTEE IS NOT RESPONSIBLE
FOR ANY CHANGES OR MODIFICATIONS
NOT EXPRESSLY APPROVED BY THE PARTY
RESPONSIBLE FOR COMPLIANCE. SUCH
MODIFICATIONS COULD VOID THE USER’S
AUTHORITY TO OPERATE THE EQUIPMENT.
This equipment complies with the FCC RF radiation
exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with
a minimum distance of 20 centimeters between the
radiator and your body.