5.1.2.2 Rhythm of the ACT indicator on the CPUBDT board
The slow rhythm of the ACT indicator shows that the niveau2.exe application is running
5.1.2.3 Display of the NeTIS-B software version
Connect a screen and keyboard
Then press the "Escape" key on the keyboard and eventually stop the screen from scrolling in
order to find the following line:
******* TETRA BS L2P LINUX SOFTWARE FOR PC V 7.04/b (C) ETELM 2008 DJ
***72*****
Here the niveau2 version is: 7.04/b
The display of the software version indicates that the niveau2.exe application is running and
has not abounded.
5.1.3 N
E
TIS-B
IP
CONFIGURATION
Once the application is running you can check the settings for the network board. This is
useful for updating versions or remotely controlling the board using PUTTY, WinSCP (See
chapters)
Press the ALT+F2 keys to scroll pages
The data on the Ethernet interface board are displayed in red below