Maintenance Guide Part 1

NeTIS MAINTENANCE GUIDE – Version 1.1 15/139
2g 'REF’ Presence of a synchronisation by link (communications board)
2f 'GPS’ This indicator has different flashing frequencies,
State 1: On 100ms / Off 100 ms No GPS module or defective GPS module
State 2: On 100ms / Off 900 ms GPS module OK / Satellite acquisition in
progress
State 3: On 100ms / Off 5 s Module GPS OK / Antenna fault
State 4: On 1 s / Off 1 s GPS module OK / Satellites OK
State 5: On 2s / Off 2s GPS module OK / Satellites lost, synchronisation
maintained for 8 min 30 s before switching to the internal reference
The board's synchronisation source can be determined from the indicator states,
'LOC’ off whatever the state of the other indicators means synchronisation on the internal
reference
'LOC’ and 'REF’ on mean synchronisation on the link
'LOC’ on and 'REF’ off and 'GPS’ state4 or state5 means synchronisation on the GPS
The clock test connector is controlled by selector 4
Position 0: 8 KHz (used on G703)
Position 1: 64 KHz (used on G703)
Position 2: 10 MHz (internal reference clock)
Position 3: TETRA multiframe
Position 4: TETRA frame
Position 5: TETRA time slot
Position 6: 2,048 MHz (G703)
Position 7: TETRA symbols
Clock signal selector on test connector 3
GPS antenna connector
Opening for access to the clock frequency internal reference fine tuning potentiometer
for the base station
Keyboard and mouse connector (diagnosis mode only)
Reset push button - this push button is accessible using a pointed object. Launching
this command triggers a restart of the software which is indicated by a tone on the
restart
COM1 serial connector
RJ45 connector for LAN network
Video connector for local screen connection (diagnosis mode only)
4
5
6
8
9
10
11