Specification

R4-G19AT
4" LINE VOLTAGE GU-10 NON IC NEW CONSTRUCTION HOUSING
120V- Non IC AIRTIGHT GU-10
Project
Location
PRODUCT DESCRIPTION
COMPATIBLE TRIMS
Model Description Finish
R4-493 3" BAFFLLE TRIM MR16
matte white, brushed nickel
R4-421 4" ALZAK TRIM MR16
matte white, chrome w/ clear, matte white w/ clear, brushed w/clear
R4-488 4" 35 DEGREE ADJUSTABLE SPOT TRIM MR16
matte white, brushed
R4-409 4" SHOWER TRIM W/FROST GLASS MR16
matte white, brushed nickel
R4-497 4" 90 DEGREE DROP ADJUSTABLE MR16
matte white, brushed nickel
R4-555 4" SQUARE APERTURE W/SQUARE TRIM RING
matte white, brushed nickel
R4-559 4" SQUARE SHOWER TRIM W/SQUARE TRIM RING
matte white, brushed nickel
R4-588 4' SQUARE 35 DEGREE ADJUSTABLE SPOT
matte white, brushed nickel
R4-589 4" SQUARE TRIM WITH REFLECTOR
matte white, brushed nickel
R4-590 4" SQURE BAFFLE TRIM MR 16
matte white, brushed nickel
R4-DS90 4" SQUARE BAFFLE TRIM MR16
matte white, brushed nickel
R4-593 4" SQUARE BAFFLE TRIM MR16
matte white, brushed nickel
R4-521 4" SQUARE ALZAK TRIM MR16
matte white, chrome w/clear, matte white w/clear
R4-597 4" SQUARE 90 DEGREE DROP ADJUSTABLE MR16
matte white, brushed nickel
R4-587 4" SQUARE REGRESSED ADJUSTABLE REFLECTOR TRIM
matte white, brushed nickel
R4-508 4" SQUARE SHOWER TRIM MR16
matte white, brushed nickel
R4-520 4" SQUARE TRIM W/PINHOLE ADJUSTABLE MR16
matte white, brushed nickel
R4-DR488 4" DIECAST GIMBLE TRIM MR16
matte white, brushed nickel
R4-DR88 4" DIECAST GIMBLE TRIM MR16
matte white
LABELS: ETL/CETL listed ETL listed number: 4005878) ETL listed for
through-branch wiring (8) No. 12 AWG 90°C and damp locations.
R4-G19AT housing is designed for NON-IC rated ceiling. Accommodates up
to 50W GU10 Halogen & LED lamps.
SPECIFICATIONS
HOUSING: Low 4" profile for shallow ceilings. Pre-wired .037" steel housing
adjusts up to 1 3/4" ceiling thickness. Trim is secured with torsion wing
springs/standard coil springs. Designed to be installed in existing sheet rock
ceilings via ceiling cut out (above ceiling access is not required). Non IC rated
housing must be kept 3" from insulation.
AIR FLOW RESTRICTION: Airtight models are designed to restrict air
flow from room into plenums in compliance to the WSEC-Washington State
Energy Code (less than 2.0 CFM-Cubic Feet per Minutes)
MOUNTING FRAME: Supplied with (2) 24" adjustable bar hangers . Bar
hangers equipped with (nail-less installation) 3/4" serrated barbed studs for
secure mounting in wood joists.
JUNCTION BOX: Pre-wired, galvanized steel J-box with (4) knock-outs.
Strain clamps and ground wire. Equipped with safety standard thermal
protector rated for 90°C.
135mm[5
1/2"]
200mm[8"]
138mm[5
1/2"]
102mm[4"]

Summary of content (1 pages)