To quickly see which tracks and TRACK PARAMETER pages that contain scene locks, press and hold a
[SCENE] key. The [TRACK] keys of all tracks containing scene locks will turn half-bright green and/or
start to blink. Selecting one of these tracks will show half-bright green and/or blinking [TRACK PARAM-
ETER] keys. They indicate which TRACK PARAMETER pages that contain scene locks.
10.3.2 SCENE VOLUME LOCKING
Certain parameters specially made for volume fades are available exclusively to scenes. The XLV, XVOL
and XDIR parameters can be regarded as a set of extra volume controllers on top of the LEVEL, VOL
and DIR parameters. The dierence lies in the way they handle volume fades. Locking them accordingly
will make the crossfader fade between the volume of the tracks or inputs in an equal energy fashion.
This way of locking volumes is suitable when wanting to avoid the volume dip that otherwise would occur
when the crossfader is used to fade between two tracks and reaches the center position.
The parameters are only visible when keeping a [SCENE] key pressed. The XLV parameter is found as
an overlay to the LEVEL parameter found in all TRACK PARAMETER pages. The XVOL parameter is
found in the AMP MAIN menu. The XDIR AB and XDIR CD parameters are found in the MIXER menu.
The XLV parameter can be locked to two settings.
MIN will mute the signal, post track eects.
MAX will let signal through at the set LEVEL signal level.
The XVOL parameter (on the AMP menu) can be locked to two settings.
MIN will mute the signal, pre track eects.
MAX will let signal through at the set VOL signal level.
The two XDIR parameters (on the MIXER menu) can each be locked to two settings.
MIN will mute the signal.
MAX will let signal through at the set DIR signal level.
Pressing the LEVEL knob while holding down the [SCENE] key pressed will remove
the LEVEL lock. An XVOL lock is removed by pressing the corresponding DATA ENTRY
knob while keeping the [SCENE] key pressed. An XDIR AB lock is removed by pressing
knob B while keeping the [SCENE] key pressed. XDIR CD is removed by pressing knob
C while keeping the [SCENE] key pressed.
10.3.3 SCENE MUTE
Mute a scene assigned to a scene slot by pressing [FUNC] + [SCENE A]/[SCENE B]. When muting a
scene the locked parameters of assigned scene will be disregarded and instead the general parameter
values of the active part will come into eect. This makes it possible, given the scene parameter values
are locked accordingly and the position of the crossfader fully activates the scene, to for example apply
washes of eects by unmuting a muted scene.
10.3.4 SCENE COPY
It is possible to copy a scene and paste it to a new scene location.
To copy a scene assigned to scene slot A or B, press and hold a [SCENE] key and press [RECORD].
A window saying “COPY SCENE” will appear. Paste a scene by holding a [SCENE] key and pressing
[STOP]. A window showing “PASTE SCENE” will be shown. The copied scene will be pasted to the loca-
tion of the scene assigned to the scene slot.
10.3.5 SCENE CLEAR
It is possible to clear all scene parameter lock data from a scene.
Hold a [SCENE] key and press [PLAY]. A window saying “CLEAR SCENE” will appear. The scene as-
signed to the scene slot will be cleared.
The clear scene operation can be undone by performing the operation one more time. The message
“UNDO SCENE” will be shown in the display.