XVOL is a setting that only will appear when pressing a [SCENE] key. This parameter can only be
locked to scenes. For more information, please see “10.3 SCENES” on page 53.
11.4.6 AMP SETUP
Open the AMP SETUP menu by either pressing [FUNC] + [AMP] or quickly double pressing [AMP]. The
graphical envelope shows which parameters control which aspect of the envelope. It is a static image
and doesn’t reflect the current envelope settings.
AMP controls the behavior of the amplitude envelope.
• ANLG will make the envelope attack start from the current envelope level when a sample is
trigged.
• RTRG will make the amplitude envelope start from zero every time a sample is being trigged.
• R+T will make the amplitude envelope start from zero every time a sample trig or a trigless trig is
activated by the sequencer.
• TTRG will make the envelope attack start from the current envelope level when a sample or a
trigless trig is activated.
SYNC sets if the amplitude envelope should be synced to the Octatrack MKII BPM or not.
ATCK sets how the attack of the envelope should behave.
• LIN will make the envelope attack work in a linear fashion.
• LOG will make the envelope attack work in an exponential fashion. This setting allows for more
smooth fade ins.
FX1 controls how the envelope will aect the multi mode filter or the amplitude modulator when either
of these eects are assigned to eect block 1.
• ANLG will, if the multi mode filter is assigned to FX1, make the filter envelope start from the cur-
rent envelope level instead of starting from zero when a sample trig is being trigged. Instead, the fil-
ter envelope attack will start from the current envelope level. If the amplitude modulator is assigned
to FX1 the phase will be restarted each time a sample trig is trigged.
• RTRG will, if the multi mode filter is assigned to FX1, make the filter envelope start from zero every
time a sample trig is being trigged. If the amplitude modulator is assigned to FX1 the phase will be
restarted each time a sample trig is trigged.
• R+T will, if the multi mode filter is assigned to FX1, make the filter envelope start from zero every
time a sample trig or a trigless trig is activated by the sequencer. If the amplitude modulator is as-
signed to FX1 the phase will be restarted each time a sample trig or a trigless trig is being activated.
• TTRG will, if the multi mode filter is assigned to FX1, make the filter envelope start from the cur-
rent envelope level instead of starting from zero when a sample trig or trigless trig is being trigged.
If the amplitude modulator is assigned to FX1 the phase will be restarted each time a sample trig or
a trigless trig is trigged.
FX2 works just like FX1 parameter. It only aects the multi mode filter or amplitude modulator when
either of these eects are assigned to the second eects slot.
FX1 and FX1 AMP SETUP parameters are the only TRACK PAGE parameters, apart from
the EFFECT pages, that are available to a master track.
11.4.7 LFO MAIN
Here the speed and depth settings of the three track LFOs are found. LFOs are always synced to the
tempo of the Octatrack MKII. Press the [LFO] key to access this page.