Error
code
Message in App Description Possible cause
F02 Contact Service. 5 sec. beep from Receiver
Fire is not responding; no ignition
Microswitch not making contact with cam on motor knob
Motor wiring is incorrect
Reversed polarity or faulty Microswitch
Bent Motor Knob
F03
Contact Service.
5 sec. beep from Receiver
Ignition process is interrupted
Fire is not responding; no ignition
Thermocouple wiring is incorrect
Thermocouple wiring is not connected
ON / OFF switch in O (OFF) position
F04 Ignition Sequence
Malfunction.
Wait 1 minute. Retry
ignition.
No pilot flame within 30 sec.
NOTE: After 3 failed ignition sequences F06
shown
No gas supply
Air in pilot supply line
No spark
Reversed polarity in thermocouple wiring
Check for correct pilot orifice (LPG to NG or vice versa)
F05 Contact Service. Pilot burner fails to ignite or shuts off
Motor stays in pilot position
Not enough thermo-voltage
Air in the pilot supply line
Low inlet pressure
Bad thermocouple
F06 Contact Service. 3 failed ignition sequences within 5 minutes
Fire is not responding; no pilot flame
No gas supply
Air in pilot supply line
No spark
Reversed polarity in thermocouple wiring
Check for correct pilot orifice (LPG to NG or vice versa)
F07 Replace Handset
Batteries.
Battery icon flashes on handset display Low battery power in handset
F08 Contact Service. Low Receiver battery power supply
Short beeps for 3 sec. during motor turn
Low Receiver battery power supply
F10 Contact Service. Pilot lit
Main burner fails to ignite and pilot shuts off
Ignition is blocked for 2 minutes
2nd thermocouple is out of position
2nd thermocouple wiring is incorrect
Gas logs out of position
Gas ports for burner are blocked
F12 Contact Service. Motor turns to pilot position Receiver powered by batteries and Receiver temperature exceeds 60 °C
Check air circulation and heat shield
F13 Contact Service. Motor turns to pilot position
Fan at level 4 for 10 minutes (T > 80 °C)
Receiver temperature exceeds 80°C
Check air circulation and heat shield
F14 Contact Service. 5 sec. beep from Receiver
Fire is not responding; no ignition
Receiver software doesn’t support a 2nd thermocouple
Wrong Receiver
F15 Contact Service. 5 sec. beep from Receiver
Fire is not responding; no ignition
2nd thermocouple wiring is incorrect
2nd thermocouple wiring is not connected
F16 Handset out of range. No temperature shown in App Handset out of range for more than 1.5 h
Electrical interference
F17 Contact Service. Fire is not responding; no ignition Inlet voltage exceeds 7.25 V
Malfunction of Mains Adapter
F18 Contact Service. Switch panel / touch pad not functioning Switch panel / touch pad is locked
Short in cable or button
F19 Contact Service. Pilot drops when Motor opens main gas Insufficient thermo-voltage
Thermocouple malfunction
Low inlet gas pressure
Improper thermocouple flame impingement
Carbon build-up on thermocouple
Valve malfunction
Resistance in thermocurrent circuit
F26 Contact Service. It is not possible to increase flame height
after ignition
Fan at level 4 for 10 minutes (T > 80 °C)
Receiver powered by batteries and Receiver temperature exceeds 60°C
Receiver powered by mains power and Receiver temperature exceeds
80°C
F27 Contact Service. Fire is not responding
No electronic control of fire
No handset or Wi-Fi Box connected to Receiver for more than 3 hours
F28 On-Demand Pilot Pilot shuts off after a predefined time Pilot shuts off after no motor movement for a predetermined time
B ERRORS CODES PROCONTROL APP
B.1 Messages shown in app