Warranty

NATURAL GAS CONVERSION INSTRUCTION
9
10
11
Disconnect the bellows from brass fitting.
Disconnect the Orifice Holder and LP orifice spud from the Venturi tube
(Air mixer).
Connect
1
1
2
2
Pull out the stainless steel net from the Venturi tube(Air mixer).
Make sure no spider nets or other debris in the tube.
Locate the new NG orifice spud, verify it is the correct size, the sign
3.71mm should be on the side of the orifice spud.
Screw the new NG orifice spud into the Venturi tube(Air mixer).
Re-attach bellows to the NG orifice spud.
Disconnect
Venturi tube(Air mixer)
Bellows
Orifice Holder
LP Orifice Spud
1
2
Venturi tube(Air mixer)
Bellows
3.71
1
2
Although your unit’s burner
may vary, conversion
method is the same.
Although your unit’s burner
may vary, conversion
method is the same.
8 / 40