Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A Copyright © Elenco® Electronics, Inc.
DC POWER SUPPLY 1 2 13 4 5 CURRENT VOLTAGE C.C. C.V. 6 7 FINE COARSE ON FINE OFF – 3 COARSE GND + 8 POWER 9 10 1. Voltage Meter 2. Ammeter 3. Coarse Voltage Adjustment 4. Fine Voltage Adjustment 5. Coarse Current Adjustment 6. Fine Current Adjustment 7. Constant Current Mode Indicator LED 8. Constant Voltage Mode Indicator LED 9. Power Switch 10. Negative Output Terminal 11. Ground Terminal 12. Positive Output Terminal 13. Zero Adjust (XP-605 only) 14. AC Input Voltage Switch 15.
INTRODUCTION Congratulations on your selection of a top quality power supply! The XP-605 has an output of 0-30VDC @ 5A; the XP752A has an output of 0-50VDC @ 3A. Their features include fine and coarse controls for voltage and current, and contains two analog volt/amp meters (XP-605); two digital volt/amp meters (XP-752A). The supply incorporates an externally controlled current cutoff circuit with an LED indicating current overload. Protected against short circuits and overloads.
OPERATING INSTRUCTIONS 1. Set the AC input voltage switch on the back to the correct setting and the correct fuse (6A - 115V, 3A - 230V) installed. 2. Set the power switch to the off position. 3. Plug the power cord into the power socket on the back of the unit. 4. Plug the power cord into an AC output. Note: Make sure enough space is left for heat dissipation. 5. Check that the voltage rating of the equipment does not exceed the power supply’s rating. Constant Voltage Mode 1.
Note XP-752A: Current limiting less than 1/2A or a shorted output activates the short circuit protection, turning the unit off. To reset unit, remove the short or load and readjust current limiting control. Setting Current Limit Protection Mode 1. Adjust the current and voltage control knobs to the desired output voltage. 2. Short the positive to the negative output terminal. 3. Press the power ON/OFF switch to ON. The CC LED should be lit. 4. Turn the voltage coarse knob clockwise 1/4 turn. 5.
• Never move or pull the power supply using the power cord or output lead. • The unit is designed for INDOOR USE ONLY. SPECIFICATIONS Model Output Current Line Regulation Load Regulation Ripple & Noise CV CV CV CC CC CC XP-752A 0-50V 3A < 0.01% +1mV < 0.2% +1mA < 0.01% +3mV < 0.2% +3mA < 0.5mV rms < 3mA rms XP-605 0-30V 5A < 0.01% +1mV < 0.2% +1mA < 0.01% +3mV < 0.2% +3mA < 0.5mV rms < 3A < 3A < 3A < 0.01% +5mV < 0.2% +5mA < 1.
MAINTENANCE Cleaning – Using a soft moistened cloth, remove any dirt on the outside of the case. The power supply should be used in a normal working environment. Servicing – If the unit becomes inoperative or damage, Elenco® Electronics or a qualified repairperson should only perform the repair and calibration. Fuse Replacement The power supply will not work if the fuse is blown or not installed. Check and repair any existing problems before installing new fuse.
TWO YEAR WARRANTY All Elenco® models are guaranteed for two full years on all parts and service. For the first 3 months, your power supply is covered at absolutely no charge. For the remaining 21 months, a nominal service charge is required to cover shipping and handling. When returning merchandise for repair, please include proof of purchase, a brief letter of explanation of problem, and sufficient packing material.