User's Manual

3.9 Safety instructions on electrical installation
Work on the electric system of the used equipment must
only be carried out by authorized electricians according to
applicable rules and regulations by the trade association,
particularly the provisions of DIN VDE 0100. Additionally,
the national legal regulations of the respective country of
operation must be observed.
In case of defects like loose connections or defective or
damaged cables on the system, the product must not put
into operation.
Prior to any inspection, installation or disassembly work,
the system (blinds, shutter) must be disconnected from
the voltage.
All electrical connections, safety equipment, safeguards
etc. must be properly installed, connected and grounded.
The power connection must be designed according to the
information in the electrical circuit diagram (type and level
of voltage).
One circuit breaker is suf cient to disconnect the system
from the mains supply (if only one phase and neutral is
used).
If one xed (stationary installed) drive system is not
equipped with a mains cable with plug or other means
of disconnection from the mains supply with a contact
opening width according to the provisions of overvoltage
category II (according to IEC 60664-1) for full disconnect,
an isolating device of this kind must be installed into the
xed electrical installation according to the installation
regulations.
Mains connection cables for drive systems with rubber
hose cables (code 60245 IEC 53) must always be repla-
ced by cables of the same type.
The following applies for drive systems with access to
unprotected, movable parts after installation: Movable
parts of the drive system must be installed at least 2.5 m
above the ground (or another level providing access to
the drive system).
4 Product description
The RolTop-915 is a wireless-controlled electromechanical
tubular motor drive. During operation it carries out radial
movements.
Commissioning of the RolTop-915 with elero installation
cable or transmitter for con guration of various functions.
Fabric protection system with retraction
Fabric relief function (Fabric protection system)
Relief function and retraction for fabric protection are only
active in wireless operation.
The values for your RolTop-915 model can be found on
the name plate.
Depending on torque and size, the different models of the
RolTop-915 are equipped with different types of braking
systems. This may lead to different operating properties
e. g. when approaching an end position.
4 | US+CA © elero GmbH
Safety | Product description
3.6 Safety instructions on technical condition
Prior to installation the product must be checked for
damage and proper condition.
The operator is obliged to only operate the product in
technically awless and operationally safe condition. The
technical condition must comply with statutory require-
ments applicable at the date of manufacturing stated on
the name plate.
If dangers for personnel or changes in the operational
behavior are identi ed, the product must be put out of
operation immediately and the operator must be informed
on the incident.
Without approval by the manufacturer, no modi cation,
extensions or alterations must be carried out on the
product.
The system must be regularly checked for imbalance or
signs of wear or damaged cables and springs (if appli-
cable).
3.7 Safety instructions on transport,
assembly and installation
In general, the respective transport company is responsible
for transporting the product. The following safety require-
ments must be observed during transport, assembly and
installation of the product:
During transport, the product must be secured according
to the regulations of the used means of transport.
For transport, only hoisting equipment and suspension
gear must be used that are appropriately dimensioned
for safely handling the forces occurring during loading,
unloading and assembly of the product.
Only points de ned for hoisting or suspension at the
pallet and the product must be used for hoisting or sus-
pension.
If work must be carried out under suspended parts or
working equipment, these must be secured against falling
by suitable means. It must be ensured by suitable hois-
ting equipment that loads drift unintentionally, fall or get
unhooked unsupervised.
Standing under suspended loads is forbidden.
During loading with hoisting equipment, a safety helmet
must be worn.
Assembly and installation must generally only be carried
out by trained and suitably instructed specialists.
The rated torque and the rated operating time must be
suitable for the properties of the driven component („fa-
bric“).
Decisive for the determination of the drive system is the
drive computation program of the manufacturer.
The smallest internal tube diameter for the winding shaft
is 36 mm for RolTop-915 type S, 47 mm for RolTop-915
type M and 58 mm for RolTop-915 type L.
Access to the drive system must be ensured by a freely
accessible appropriately sized inspection ap that can
easily be opened.
3.8 Safety instructions on operation
Before initial commissioning, the operator is obliged to
inspect the product for safe and proper operation.
Inspections must also be carried out during operation of
the product in regular intervals de ned by the operator.