AUDIO SECTION
Nominal Input Level (±50kHz dev.) ................................................................................................................... -10 to +8dBm
Input Impedance ............................................................................................................................................ 600 balanced
Pre-emphasis .................................................................................................................................................................. 50µs
Transmission characteristics
Amplitude Frequency Response ......................................................................................................... 40 to 15000Hz ±0.5dB
Total Harmonic Distortion ........................................................................................................................................... < 0.5%
FM Signal to noise ratio (referred to ±50kHz dev. f = 400Hz) .................................................................... > 60dB (weighted)
AM Signal to nokise ratio ............................................................................................................. > 50dB (referred to 100%)
AM Synchronous Modulation ..................................................................................................... > 40dB (referred to 100%)
METERING
Output Forward Power (Peak or RMS)
Output Reflected Power (Peak or RMS)
Unbalance Power (last unbalance load in output combiner)
Transmitter Temperature
Power Amplifier Forward Power (Peak or RMS)
Power Amplifier Reflected Power (Peak or RMS)
Power Amplifier Input Power (Peak or RMS)
Power Amplifier Heatsink Temperature
Pallet Current
Power Supply Voltage
Working Timer
INDICATIONS
Cooling Blower Working (with icon on front display)
Transmitter Interlock (with icon on front display)
Alarm (with red LED on front panel)
Transmitter ON/OFF (with green LED on front panel)
Remote ON/OFF (with orange LED on front panel)
Input Mains Phase Missing (with green LED on Power Control panel)
PROTECTIONS
Mains Phase Lack
Output Forward Power
Output Reflected Power
Rack Cooling Failure
Power Amplifier Forward Power
Power Amplifier Reflected Power
Power Amplifier Heatsink Temperature
Module Current
Power Supply Voltage
REMOTE CONTROL SECTION
Parallel Interface ........................................................................................................................... ON/OFF, Alarms, Interlock
Serial Interface ...................................................................................... RS232 or RS485 (Full monitoring and management)