User's Manual Part 1

40
UHF DTV BANDPASS FILTER 06655A
TECHNICAL DATA
Frequency Range 470 - 862MHz SWR < 1.22
Configuration 6 Cavities elliptical 2
nd
Harmonic Attenuation > 80dB
Bandwidth 6 to 8MHz Group Delay Variation < 250ns
Max Output Power 2.5kW (rms) Temperature Stability < 1.5kHz / K
Insertion Loss f(0) < 0.3dB Ambient Temperature Range -10° to +50°C
Attenuation f(0) ±3.8MHz < 0.8dB (SWR 1.22), < 1dB (SWR 1.18) Weight 35kg
Attenuation f(0) ±4.2MHz > 5dB (SWR 1.22), > 6dB (SWR 1.18) Working Position Any
Attenuation f(0) ±6MHz > 30dB (SWR 1.22), > 35dB (SWR 1.18) Dimensions Max 370 x 372 x 564mm
Attenuation f(0) ±8MHz > 45dB (SWR 1.22), > 50dB (SWR 1.18) Output Connector EIA 1+5/8” Unflanged
TUNING INSTRUCTIONS
To calibrate the filter PBN153/45-6C/58, a double-track Network Analyser is needed, in order to display
the frequency response of the passing signal and the reflected one. The filter is composed by siz band-pass
cavities with coupling between intermediate cavities.
Connect the filter to the Network Analyser, marking the input. Select the middle frequency of the channel
range in the middle of the screen and set a SPAN of 50MHz.
Turn the coupling (4) (fig. 1) to the end.
Act on the tuning rods (1) (fig. 1) until the curve is displayed at the center of the screen, then act on the
interstage couplings (2) and on the IN/OUT couplings by rotating the screw (3) to obtain a band width of
about 8MHz.
Set the instrument for a SPAN of 20MHz, move the markers to the limits of the used band (Fo ±3.9MHz).