1.2 TECHNICAL CHARACTERISTICS
Human-Machine Interface
- 240x128 graphic display with CCFL backlight
- 3 general LEDs (ON, REMOTE, ALARM)
- 3 alarm LEDs for RF powers (FWD, REF, UNB)
- 4 push-buttons (ESC, RET, UP, DOWN)
Alarms resulting in the transmitter being switched off
- Fans rotation (about 10 second delay)
- Interlock (immediate, can be disabled)
- Antenna Reflected power (if configured)
Alarms not resulting in the transmitter being switched off
- Lack of communication with an Amplifier Module
- Amplifier module locally switched off
- Alarm on amplifier module
- Power in antenna or unbalancing beyond the threshold (Reflected power alarm can be configured to switch off the trans-
mitter)
Connections on the front panel
- RF Monitor on 50 BNC connector (0dBm at the nominal power)
- RS232 on DCE-type D-SUB9 female connector, for control via PC or firmware update
Connections on rear panel
- RS485 on two D-SUB9 female connectors for the connection with the Amplifier Modules
- RS485 on D-SUB9 female connector for the connection with an optional remote control device*
- Telemeasures (Forward power, Reflected power, Unbalancing, Alarm) and telecontrol (ON/OFF) on D-SUB25 female connector
- Up to 8 RF powers can be monitored on BNC connectors
- Fans rotation control on BNC connector
- Alarm on the opening of a series of switches (Interlock) on BNC connector
- Power supply +24Vdc available on two 2-poles connectors
Miscellaneous
- Real-time clock with CR2032 lithium backup battery (nominal voltage 3V, nominal capacity 210mAh)
- Alarm and event list up to 130 entries
- 100-240Vac 50/60Hz Power Supply
- 19”-3U Cabinet, deep 260mm
- 6kg Weight
- Operating Temperature -5° to +45°C
- Relative Humidity 20% - 90%
- Altitude up to 2500m
* For more information contact the Sales Department of Elettronika S.r.l. or the local distributor.