User's Manual Part 2

103
alone mode or set a slave address by means of the UP and DOWN arrow keys. The
changes made are saved by pressing the RET key or discarded pressing the ESC key.
Remote
The amplifier may be controlled either locally, by means of the keys and display, or
remotely. There are three possibilities for remote control:
- using a direct serial connection between amplifier RS232 connector and a PC RS232;
- using the remote control device manufactured by Elettronika S.r.l. (RCU), on the RS485;
- using a general-purpose control system connected to telemeasures.
You can enable / disable remote control choosing menu item Settings J Remote. When
remote control is enabled, the yellow REMOTE LED on the front panel is lit.
Interlock
One of the pins of the telemeasure connector, located on the rear panel, is used for the
interlock alarm. It is an input line which turns off the amplifier in case of alarm. The
interlock check can be enabled or disabled using menu item Settings J Interlock. When
it is enabled, the status bar shows the lock symbol, which is close if the interlock chain is
closed (no alarm) or open if it is open (alarm).
Firmware Release
The menu entry Settings J Firmware Release allows to display the firmware version
number and the hardware release of the amplifier.
Serial Number
The menu entry Settings J Serial Number allows to display the serial number of the
apparatus.