User Manual

58
V
This is a read-only parameter that shows the voltage of the RF amplifier stage, measured
in Volt. If this value is outside the normal range, an alarm occurs and the value on the
display blinks.
I
This is a read-only parameter that shows the current absorbed by the RF amplifier stage,
measured in Ampere. If this value is outside the normal range, an alarm occurs and the
value on the display blinks.
Lockout (Present, Absent)
This read-only parameter shows whether the lockout condition is present or absent. In
case of presence of lockout, the label blinks (see the Alarms and automation paragraph
for more information).
Reset Lockout
This is an “action” parameter that allows to reset the lockout condition. If the lockout isn’t
present, nothing happens (see the Alarms and automation paragraph for more
information).
Fwd max
This parameter indicates the threshold of the output power. If the output power is higher
than this threshold, an alarm occurs (see the Alarms and automation paragraph for
more information).
Ref max
This parameter indicates the threshold of the reflected power. If the reflected power is
higher than this threshold, an alarm occurs (see the Alarms and automation paragraph
for more information).
- AMPLIFIER submenu