User's Manual Part 1

43
- RF Amplifier Module Section
EXIT
Clicking on the knob, after selecting this voice, goes back to the default menu.
LockOut
Shows whether the LockOut state is present or absent. In case of presence of LockOut, the label blinks.
Below is detailed the functioning of LockOut.
While an alarm is present the exciter switch off the output power. When the alarm disappear, the power is
switched on again. After 5 times the exciter switch off the output power, the exciter goes in LockOut state: the
power remains off till the user reset the LockOut. If the fails are far more that 1 hour than the LockOut counter
is automatically cleaned.
ResetLockOut
Clicking on then knob, after selecting this voice, goes into the menu that allows to clear
LockOut counter.
Answer to the confirming question, selecting between accept or not. The answer starts
always from "Accept: NO", so to exit quickly form this menu simply click 2 times on the knob.
Voltage
Shows the measure of the power supply voltage of the final power stage. In case of abnormal value, the label
blinks.
Current
Shows the measure of the power supply current of the final power stage. In case of abnormal value, the label
blinks.
Temp.
Shows the measure of the working temperature of the final power stage. In case of abnormal value, the label
blinks.
Fan
Shows the operating mode of the fan, which may run at low or high speed, be still or be programmed to work