User's Manual Part 1

54
2.6 VEGA FACTORY SETTING
The VEGA display board stores some settings and fine tunings inside its not erasable memory. The storing
occurs while the VEGA is tested in factory before the sell. To enter in Factory Setting mode a dip-switch is
used.
DIP2 On (VEGA display board): Factory setting.
Note that DIP2 is set to ON only during the factory setup of the exciter. This allow to store in the memory all
of the settings made as factory defaults. Once the test is completed, and while the modulator is used normally,
the DIP2 must be kept OFF.
One of the factory setting stored during this phase is the set point of all the digital trimmer in the menu list. If
you take a look at a digital trimmer it has two wiper: one is filled and the other is empty. The filled can be
moved ONLY during the phase of Factory Setting. In this way, during the normal operation of VEGA, if the
user try to move a set point and forget the original value can easily go back to the factory set point, without any
instrumentation.
All other settings available in the phase of Factory Setting are present in some hidden menu described below.
All the hidden menu are located at the right of the Front menu.
Fwd Max
Clicking on then knob, after selecting this voice, goes into the menu that allows to
change the trigger point of the Forward Max alarm. Rotate the knob to select the desired
value and click on it.
Reflected Max
Clicking on then knob, after selecting this voice, goes into the menu that allows to
change the trigger point of the Reflected Max alarm. Rotate the knob to select the
desired value and click on it.