2.1 OPERATING ENVIRONMENT
You can install the apparatus in a standard component rack or on a suitable surface such as a bench or
desk. In any case, the area should be as clean and well-ventilated as possible. Always allow for at least
2 cm of clearance under the unit for ventilation. If you set the apparatus on a flat surface, install spacers
on the bottom cover plate. If you install the apparatus in a rack, provide adequate clearance above and
below. Do not locate the apparatus directly above a hot piece of equipment.
2.2 PRELIMINARY OPERATIONS
Correct installation of the equipment is important for maximum performance and reliability. Antenna
and earth connections must be installed with the greatest care. The equipment adjustment isn’t need,
because the unit is completely adjusted by our technical staff. This is the installation procedure:
1. connect the power supply cable of the transmitter to the auxiliary socket on the rear panel of the
amplifier;
2. connect the power supply cable of the amplifier to the electric network (230VAC). If there is the Isolator
Transformer, the amplifier is provided with cable and plug;
3. connect the exciter / antenna cable to the RF IN and RF OUT on the rear panel of the amplifier.
WARNING!!!
FOR ELECTRICAL SAFETY REASONS AND IN ORDER TO KEEP THE APPARATUS SAFE,
THE GROUND TERMINAL OF THE APPARATUS MUST BE CONNECTED TO THE EX-
ISTING GROUNDING SYSTEM AND NOT BY USING THE SHIELD OF THE OUTPUT
COAXIAL CABLE.