User's Manual Part 1

27
- RF Powers
This is the main screen showing the RF powers of the amplifier: forward power, reflected power, unbalances,
if any. For forward power a level bar is displayed. See an example in Figure 1.
- Power Supply
This screen shows all the signals coming from two power supply. To check the next (previous) power supply
press the UP (DOWN) key. For each power supply, the voltage, the absorbed current and the status (ON or
OFF) are shown.
Figure 6: Power supply screen
- Log/Alarms
The control board is provided with an external EEPROM and a clock. Any alarm or switching event with the
time at which it occurred is saved in the EEPROM. The Log/Alarms sub-menu allows to manage this log.
It is possible to see the events stored in the log by selecting Log/Alarms View Log/Alarms. All events
can be scrolled by pressing the UP and DOWN keys. For example, the event shown in Figure 7 is the turning
on of the amplifier by means of the local switch. For every event/alarm a short description and the date and
time at which it occurred is displayed.
Figure 7: Event stored in the log