Always Connected. Always Covered.
Preface As this is the full User Manual, a working knowledge of Z-Wave automation terminology and concepts will be assumed. If you are a basic user, please visit www.domeha.com for instructions.
Table of Contents Preface. . ................................................................................................................................ 2 Description & Features. . .................................................................................................... 4 Specifications. . .................................................................................................................... 5 Physical Characteristics..............................................................
Description & Features The Dome Mouser is a battery powered Z-Wave Plus enabled mousetrap that works by electrocution and is designed to be humane and painless to the rodent. After a mouse is caught, the Mouser will send a Z-Wave signal to its controller to notify the user, and will not retrigger until the trap is reset.
Specifications Technical Specifications Radio protocol Power supply Max Current Power Consumption Radio frequency Z-Wave Range Dimensions (L x W x H) Z-Wave Plus (500 series) 4x 1.5V AA Size 100mA 0.6W 908.4 MHz US Up to 150’ depending on environment 8.5” x 4.5” x 5” Table 1 - Technical Specifications Package Contents: WARNING This product was created to kill mice by electrocution. It emits a high voltage electric shock. DO NOT allow children to play with or be anywhere near this device.
Physical Characteristics The names used in Figures 1 & 2 will be used throughout this manual. Please refer to this page as needed.
Inclusion & Exclusion Inclusion Follow the instructions for your Z-Wave Certified controller to enter inclusion mode. When prompted by the controller: 1. Bring the Mouser to within 10’ of your Z-Wave controller for the inclusion process. After successful pairing, the device can be brought to the desired location. 2. Remove top cover by sliding it back and lifting up. 3. Insert batteries. 4. Press the CONNECT BUTTON quickly 3 times in a row.
Factory Reset & Misc. Functions Resetting the Mouser If needed, the Mouser can be reset locally by following these steps. Only do this when your Z-Wave controller is disconnected or otherwise unreachable. Beware that resetting your device will disconnect it from the system: 1. Remove the TOP COVER and confirm that your Mouser is powered up. 2. Press and hold the CONNECT BUTTON for at least 10 seconds then release. A flashing LED INDICATOR indicates a successful factory reset. 3.
Physical Installation How to Use—Baiting the Trap 1. Lift the BAIT HOLDER from the Mouser. 2. Add bait - dry foods (like peanuts) leave less mess. 3. Replace the BAIT HOLDER. How to Use—Setting the Trap 1. Bait the Mouser. 2. Place the Mouser in the desired location - rodents usually scurry around walls and other corners. 3. Flip On/Off Button to the On position - the LED will stay lit for two seconds indicating the Mouser is armed. A flashing LED indicates low battery. 4. When the Mouser is tripped.
LED Behavior Color Behavior This happens when… Blink 5 times in 5 seconds (slow) …the Mouser was just powered on, but is not yet included in a system. Blink 5 times in 2.5 seconds (medium) …the CONNECT BUTTON is pressed 3 times quickly (regardless of inclusion status.) Blink 5 times in 1.5 seconds (fast) …the Mouser is powered on, and already included in a system.
Button Behavior Action Condition Result Press and hold CONNECT BUTTON for 2 seconds Mouser Already Included in System Device sends a wake up notification to its controller, awaits further instructions, and blinks the LED Indicator once Mouser Already Included in System Device sends node info to Group 1 Mouser Already Included, and Controller is in Exclusion Mode Device is excluded from the system and removes the Home ID from its memory Mouser Not Yet Included in System, and Controller is in Inclu
Compatible Command Classes Command Class Notes Device Reset Locally V1 (5A) - Powerlevel V1 (73) - Association Group Information V1 (59) - Battery V1(80) Returned Value: 01 06 00 0C 07 0C 07 Z-Wave Plus Version: 01 Z-Wave Plus Info V2 (5E) Role Type: 06 (Slave Sleeping Reporting) Node Type: 00 (Z-Wave Plus Node) Installer Icon Type: 0C 07 (Home Security Alarm) User Icon Type: 0C 07 (Home Security Alarm) Returned Value: 06 04 05 03 10 52 00 Z-Wave Library Type: 06 (Enhanced Slave) Version V2 (86) P
Command Class Notes The Mouser sends a Notification Report when the trap is triggered, reset, armed, and disarmed. It primarily uses the Pest Control Notification Type, but also sends a Home Security, Motion Detected (Unknown Location) Report when the trap is triggered and a Home Security, Event Inactive when the trap is reset to ensure compatibility with all Z-Wave Controllers.
“Configuration” Command Class Parameters Configuration parameters are sent using a standard syntax to ensure interoperability between all manufacturers’ products. All values are represented using the hexadecimal number system. Typical syntax is as shown below. Note that the value sent must be the exact size, in bytes, as accepted by the setting. The “extra” spaces should be filled with zeros (see the “value” column below.
Param # Size Name Available Settings Default Setting This parameter enables or disables the indicator LED alarm when the trap is tripped. 4 01 Enable/Disable LED Alarm 00 (LED Alarm Disabled) 01 (LED Alarm Enabeled) 01 (LED Alarm Enabeled) This parameter sets the amount of time the LED Indicator blinks after the trap is tripped.
Troubleshooting Q Q: Help! My Mouser paired successfully, but my controller can’t see it anymore after I installed it! A A: The Z-Wave signal is probably weak in that area of your home. Remember that the 120' - 150' range doesn’t take into account walls, furniture, and other obstacles. To boost your Z-Wave network coverage, add a few non-battery powered Z-Wave devices between the controller and the furthest device, like the Dome On/Off Plug or Water Main Shut-Off.
Warranty & Support If you have questions, our trained Customer Service Department is happy to assist you 24 hours a day, 7 days a week. Contact Dome Customer Service as follows: • In North America dial: 1-855-249-1754 • Email Dome at support@domeHA.