Specifications

SW 5550AE • SW 3700AE • SW 1850AE Operation
Operation Manual 3-5
3.3.2 PROGRAM Menu
The PROGRAM menu allows you to:
Select a phase
Program amplitudefunction polarity validates the amplitude input,
see Section 3.4 for more information
Program current limit, either value or level
Program frequencymaximum frequency is determined by the selected
waveforms for each phase, see Section 3.4, Front Panel Programming
Conventions, for more information about maximum frequency
Program phase offset (phase offset represents a phase lead)
Select a function to be output on the selected phase.
PROGRAM
MEASURE
WAVEFORM
SEQUENCE
INSTR
SYSTEM
PHASE A (or B or C)
AMPL V
CURL A
FREQ Hz
ANG Deg
FUNC
MAIN MENU OUTPUT [OFF]
PROGRAM Menu Status and Information Data:
Menu Item
Status and Information Line
Range/Default
PHASE A
[<enter> for next phase]
Phases A, B, C
AMPL
[program output RMS/DC voltage] *
0156 V or 0312 V
(to 0.01V resolution)
CURL
[program RMS/DC current limit]
016 A or 08 A (default: 5A)
FREQ
[program output frequency] *
(default: 60 Hz)
4063 Hz or 40500 Hz
ANG
[program phase angle offset]
0360° (default: , 120°, 240°)
FUNC
[program output waveform] **
Default: Sine