Operating instructions
General Description SW 5250A•SW 3500A•SW 1750A
1-12 Operation Manual
• External Gain Control
0 to ±7.07 VDC provides zero to full scale programmed voltage output
(±2% of full scale output).
• External Input Impedance
≥30 kΩ.
• System Firmware
System firmware is stored in flash memory. This makes it possible to upgrade
the firmware without disassembling or returning the unit.
$#(
• Parallelable For Additional Power above 5250A VA
• External Waveform Creation Software
• Input Power Factor Correction to 0.99
• Test and Measurement
• 5V and 26V, 26VA Auxiliary AC outputs for 115V input, 350-450 Hz.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.