Operating instructions
SW 5250A•SW 3500A•SW 1750A Operation
Operation Manual 3-7
'%+%@%"'++
The current state of the SW can be saved and restored using the Front Panel
Store/Recall feature. The following Program Menu parameters are affected:
• Amplitude
• Current Limit
• Frequency
• Phase Angle
• Function
The Store/Recall Menu can be accessed by pressing
F2
from any Program menu edit
field. Setups are stored/recalled as a number from 0 to 49. The incr./dec. mode is not
available for this menu. Store/Recall functions do not affect the Lock/Unlock status of
the Program menu fields. If a field is locked, it will remain locked. However, the Recall
parameters for phases B and C will be updated
To store a setup:
1. Press
F2
from any Program menu edit field.
2. Move the field select cursor to “STORE SETUP.”
3. Enter a setup number from 0 to 49.
To recall a setup:
1. Press
F2
from any Program menu edit field.
2. Move the field select cursor to “RECALL SETUP.”
3. Enter the previously stored setup number from 0 to 49.