Operating instructions
Operation SW 5250A•SW 3500A•SW 1750A
3-30 Operation Manual
F4:OT Monitors power stage heat sink temperatures.
Action: Opens relays, displays error message for 30 seconds,
then shuts off SW system.
F2:OV Indicates that the internal DC bus has pumped up to an
unacceptable level (due to sinking power rather than sourcing,
i.e., attempting to discharge a very large capacitor into the SW
output too quickly).
Action: SW system tristates output amplifier until bus level
becomes normal.
UV Undervoltage: Indicates that the output voltage is less than the
programmed value, but not in the voltage foldback mode.
Action: Opens relays and displays error message.
ROC Redundant Over Current: The RMS value of the output current
has exceeded the maximum capacity of the SW.
Action: Opens relays and displays error message.
RMS_OV Monitors the external input in the “External Direct” mode to ensure
that it does not exceed 5.2 VRMS.
Action: Opens relays, displays error message, and sets
VPROGRAM to zero volts.
FLT_IN Fault-Input from Slave chassis: Represents the logical OR of
several faults.
Action: Opens relays, displays error message, and sets
VPROGRAM to zero volts. Clearing the error message
sends a fault reset to the Slave chassis. The particular
Slave chassis that had the fault will then extinguish its
fault indicator.
Table 3–6 Fault Description and Action (FR2)
RLY156,RLY312
Used for internal monitoring only.
RLY_FLT The open relay did not respond to the open/close command within
500 mSec.
Action: Programs the output to zero and attempts to change relay
state; displays error message and shuts off SW if output
relay hasn’t changed state within 500 mSecs. If unable to
clear error message, a hazardous condition may exist. Use
caution; voltage may be present at the output terminals.
Table 3–7 Fault Description and Action (FR3)