6.2  Functioning of the inputs/outputs 
6.2.1  Functioning of the inputs 
INFORMATION! 
At the inputs „Extern Enable“, “External Stop” and „switch end-pos min/max“, 
the input logic is per default/factory setting set on “low active” for security 
reasons (failsafe). 
External enable 
The extern enable input is monitored during the positioning. If the input is activated, no positioning is 
possible respectively it will be cancelled with an error message 
External start input 
corresponds to the key „start“ 
External stop 
corresponds to the key „stop“ 
Setting the reference 
If in the system parameter Reference the mode 2, 4, 6 or 8 is set, the actual value can be calibrated 
through this input. 
  Mode 2:  Reference via external input (Reference value: Parameter-Axis-Distances) 
  Mode 4:  Reference via target value + ext. input (Reference value: set target value) 
  Mode 6:  Reference positive via external Input 
  Mode 8:  Reference negative via external Input 
Incremental positioning negative 
If this input is active, the positioning in incremental is in negative direction, if incremental positioning is 
externally configured (axis parameters-> axis-> general parameters). 
Incremental positioning positive 
If this input is active, the positioning in incremental is in positive direction, if incremental positioning is 
externally configured (axis parameters-> axis-> general parameters). 
Retract function 
The retract function will be started if the input is activated 
Piece counter 
With every pulse at this input the current quantity is increased or decreased by one piece. 
Setting: Parameter-Axes- general parameter 
  decrement 
  decrement + stop 
  increment 
  increment/decrement 