Operating instructions
Diagnostics/Error Search
-40-
8 Diagnostics / Error Search
8.1 Diagnostics
Here function to test the hardware and to display the current installed hard- and software versions are
offered.
Inputs
Outputs
Keypad
Version/Info
8.2 Error Message
Check the signals/wires of the corresponding input or deactivate the according input function (see section
6.3.1 Linking the inputs with functions) when the following error messages are displayed:
"error 01: hardware end switch minimum axis X active!"
"error 02: hardware end switch minimum axis Y active!"
"error 04: hardware end switch maximum axis X active!"
"error 05: hardware end switch maximum axis Y active!"
"error 16: external stop on error active!"
"error 25: no enable!"
Check the corresponding parameter or deactivate the according software end position (see section 6.3.1
Linking the inputs with functions) when the following error messages are displayed:
"error 07: software end position minimum axis X fell below!"
"error 08: software end position minimum axis Y fell below!"
"error 10: software end position maximum axis X fell above!"
"error 11: software end position maximum axis Y fell above!"
Check the according measuring system respectively its signals/wires when the following error message is
displayed:
"error 13: no measuring system axis X!"
"error 14: no measuring system axis Y!"
At power failures below 18V all the axes are stopped, all outputs are set to 0, an error message is displayed
and the control pauses in a wait state. It can only be reactivated by connecting the power supply again.
"error 17: power failure. Switch on control again and check the axis-position!“
You have no authorisation to process this function or you have not entered a password (PIN), respectively the
wrong one when the following error message is displayed.
"error 18: access denied!"