Technical data

Table Of Contents
Technical Data
- 11 -
5. Technical Data
P40 – ELGO-position controller
Input supply voltage 24 VDC
Power input 24 VDC; max. 150 mA (no-load condition)
Rotary encoder supply unit 24 VDC or 5VDC ; max. 130 mA
Analog input (option) 12 Bit resolution ; 3,3 V Supply measuring system
Input signals The Pin assignment of the inputs and the input logic are programmable
Minimum pulse duration: 300 ms
Input current /Pin: max. 10 mA
Output signals The Pin assignment of the outputs and the output logic are programmable
Open Emitter (PNP)
Complete short-circuit-proof
Output current: max. 80 mA
Recovery diode is integrated
Actual value memory E² Prom
Durability: 10
5
On-Off-Switch-Cycle or 10 years
Connection technology Phoenix Connectors
Displays LCD Dot-Matrix 128 x 80 mm with white backlight
Hardware 32-Bit-Microprocessor with 1 MByte Flash 56 Kbyte RAM
System accuracy +/ -1 Increment
Input frequency
15 KHz (upgrade on enquiry possible) equals by 0,1 mm resolution: 120
m/min. (2 m/s)
Housing dimensions W x H x D = 144 mm x 144 mm x 40 mm (without connector)
Disruption degree W x H = 136 mm x 136 mm
Installation depth without
connector
40 mm
Installation depth with
connector
75 mm
Ambient temperature 0 to +45 °C