Technical data
Table Of Contents
- General Information
- Safety
- 3. Transport and Storage
- Product Features
- Technical Data
- Configuration and Functions
- 6.1. Elements
- 6.2. Menu, sections and parameters
- Machine setting
- If the same analog measuring system which is used for the angle also used for the angle Cutting length, then it is necessary, set the values for the cutting length calculation.
- Setting values with minimum angle: Place the cursor in the first row and first column of the table (line: min; column: S. Beg). Now, enter the smallest possible cut angle. Let down the cutting blade to beginning of the cut (till the point, where the upper beam and lower beam of the scissors just touch) and press the F2 key. Now place the cursor on the field in the first row and second column (row: Min; column: S. End) and let down the cutting blade to the end of the cut. Now press the F2 key again. Thus the values for the minimum angle are set up.
- Setting values with maximum angle:
- Place the cursor in the second row and second column of the table (line: max; column: S. Beg). Now, enter the biggest possible cut angle. Let down the cutting blade to beginning of the cut (till the point, where the upper beam and lower beam of the scissors just touch) and press the F2 key. Now place the cursor on the field in the first row and second column (row: Max; column: S. End) and let down the cutting blade to the end of the cut. Now press the F2 key again. Thus the values for the maximum angle are set up.Configuration of inputs and outputs
- 7. Operation
- 8. Interferences
- Maintenance
- Type Designation
- Accessories

Configuration and Functions
- 19 -
Tolerance window
It is possible to enter a value in this register that represents an acceptable tolerance. When the
actual position is within the tolerance the actual position displayed is aligned with the demand
position.
The entered range of tolerance is always active in the + and – range around the demand value. The
real actual value is saved in the processor, i.e. no positioning errors through adding up occur.
Example:
Entered value = 0.2 (tolerance +/ 0.2 mm)
Display without tolerance Display with tolerance
99.8 Actual display 100.0
100.0 Target window 100.0
ADVERT!
The tolerance window should be set to zero before starting to operate.
Spindle Compensation
In order to adjust spindle tolerances the demand position must be approached always from the
same direction that means that in one direction the demand position will be overrun by the entered
value. After expiration of the backlash dwell time that was entered (menu/times/backlash dwell time)
the demand position will be reached again.
Window forced tolerance
A loop is driven if the value is within the + and – range around the value oft he “window forced
loop” using absolute positioning.
Reference value
A reference value and a reference position can be entered respectively. By using the external
reference input the reference value is used as the demand value.
Retract
The retract distance can be entered in mm in this parameter.