Technical data
Table Of Contents
- General Information
- Safety
- 3. Transport and Storage
- Product Features
- Technical Data
- Configuration and Functions
- 6.1. Elements
- 6.2. Menu, sections and parameters
- Machine setting
- If the same analog measuring system which is used for the angle also used for the angle Cutting length, then it is necessary, set the values for the cutting length calculation.
- Setting values with minimum angle: Place the cursor in the first row and first column of the table (line: min; column: S. Beg). Now, enter the smallest possible cut angle. Let down the cutting blade to beginning of the cut (till the point, where the upper beam and lower beam of the scissors just touch) and press the F2 key. Now place the cursor on the field in the first row and second column (row: Min; column: S. End) and let down the cutting blade to the end of the cut. Now press the F2 key again. Thus the values for the minimum angle are set up.
- Setting values with maximum angle:
- Place the cursor in the second row and second column of the table (line: max; column: S. Beg). Now, enter the biggest possible cut angle. Let down the cutting blade to beginning of the cut (till the point, where the upper beam and lower beam of the scissors just touch) and press the F2 key. Now place the cursor on the field in the first row and second column (row: Max; column: S. End) and let down the cutting blade to the end of the cut. Now press the F2 key again. Thus the values for the maximum angle are set up.Configuration of inputs and outputs
- 7. Operation
- 8. Interferences
- Maintenance
- Type Designation
- Accessories

Configuration and Functions
-25-
D-portion
Differential voltage: setting 1...1000
General: The D-controller (differential controller) provides the control value from the derivative with respect
to time oft he offset.
P40: By offset a short voltage pulse proportional to the rate of change will be put out to compensate
quickly without sacrificing the stability of the control loop permanently. The value of the voltage
pulse is entered. (max + / - 10 V).
Pulses encoder
Rotary encoder resolution:
The encoder pulses per revolution are entered in this register. This enables the calculation of speed
to be effected (max. 10000 ppr).
Stop mode
For the different possibilities to stop the system the P40 comes with this special register.
0 = Stop smoothly (Stop ramp = negative acceleration R51)
1 = Stop abrupt (Stop ramp = highest possible negative acceleration)
2 = Stop turn off motor (Analog signal is set to zero)
v Manual fast forward
Here the fast speed can be set for moving the axes in manual mode.
v Manual slow forward
Here the slow speed can be set for moving the axes in manual mode.
v Reference mode part 1
Here the reference run speed of the back gauge until reaching the initiator is defined.
v Reference mode part 2
Here the reference run speed of the back gauge until reaching the index pulse is defined.