Technical data
Table Of Contents
- General Information
- Safety
- 3. Transport and Storage
- Product Features
- Technical Data
- Configuration and Functions
- 6.1. Elements
- 6.2. Menu, sections and parameters
- Machine setting
- If the same analog measuring system which is used for the angle also used for the angle Cutting length, then it is necessary, set the values for the cutting length calculation.
- Setting values with minimum angle: Place the cursor in the first row and first column of the table (line: min; column: S. Beg). Now, enter the smallest possible cut angle. Let down the cutting blade to beginning of the cut (till the point, where the upper beam and lower beam of the scissors just touch) and press the F2 key. Now place the cursor on the field in the first row and second column (row: Min; column: S. End) and let down the cutting blade to the end of the cut. Now press the F2 key again. Thus the values for the minimum angle are set up.
- Setting values with maximum angle:
- Place the cursor in the second row and second column of the table (line: max; column: S. Beg). Now, enter the biggest possible cut angle. Let down the cutting blade to beginning of the cut (till the point, where the upper beam and lower beam of the scissors just touch) and press the F2 key. Now place the cursor on the field in the first row and second column (row: Max; column: S. End) and let down the cutting blade to the end of the cut. Now press the F2 key again. Thus the values for the maximum angle are set up.Configuration of inputs and outputs
- 7. Operation
- 8. Interferences
- Maintenance
- Type Designation
- Accessories

-35-
Configuration of inputs and outputs
With the controller P40 it is possible to configure feely the inputs and outputs with their associated logic.
6.4.1. Link-up the inputs with functions
In the menu “Input functions” you will find an overview of all functions of the inputs which can be assigned.
After dialing a function by using the navigation buttons you can select this function by pressing the Enter key.
If a previously used input is needed to be reset, you can use the "delete key" to dial it in the "not used" state.
In the case of multiple input functions with a single external signal, the inputs can also be assigned several
times.
ADVERT!
Inputs can also be assigned several times.
6.4.2. Allocation to the logic input functions
If you are as specified in section 6.4.1 the inputs of the controller with functions, then you can use this menu
to define whether the corresponding input function to a logical "High" - level or at a logical "low". Assigning
the logic takes place by pressing the enter key.
6.4.3. Linking the outputs of functions
In the menu “Output functions” you will find an overview of all functions of the outputs which can be
assigned. After dialing a function by using the navigation buttons you can select this function by pressing the
Enter key. If a previously used output is needed to be reset, you can use the "delete key" to dial it in the "not
used" state. A repeated Assign of the outputs is not possible here and is from the outset of the software
prevented. If an output is already set with a function, then automatically only the next free output is
selectable.
ADVERT!
Outputs can not be assigned several times.
Configuration and Functions
6.4.4. Logic Allocation to Outputs
At the outputs it is also possible depending on the selected output function to assign a logic. The set follows
the same procedure as in Section 6.4.2.