Technical data
Table Of Contents
- General Information
- Safety
- 3. Transport and Storage
- Product Features
- Technical Data
- Configuration and Functions
- 6.1. Elements
- 6.2. Menu, sections and parameters
- Machine setting
- If the same analog measuring system which is used for the angle also used for the angle Cutting length, then it is necessary, set the values for the cutting length calculation.
- Setting values with minimum angle: Place the cursor in the first row and first column of the table (line: min; column: S. Beg). Now, enter the smallest possible cut angle. Let down the cutting blade to beginning of the cut (till the point, where the upper beam and lower beam of the scissors just touch) and press the F2 key. Now place the cursor on the field in the first row and second column (row: Min; column: S. End) and let down the cutting blade to the end of the cut. Now press the F2 key again. Thus the values for the minimum angle are set up.
- Setting values with maximum angle:
- Place the cursor in the second row and second column of the table (line: max; column: S. Beg). Now, enter the biggest possible cut angle. Let down the cutting blade to beginning of the cut (till the point, where the upper beam and lower beam of the scissors just touch) and press the F2 key. Now place the cursor on the field in the first row and second column (row: Max; column: S. End) and let down the cutting blade to the end of the cut. Now press the F2 key again. Thus the values for the maximum angle are set up.Configuration of inputs and outputs
- 7. Operation
- 8. Interferences
- Maintenance
- Type Designation
- Accessories

Interferences
-43-
8.4 EMC information
A trouble-free operation of the control devices of the company ELGO Electric GmbH can only be
guaranteed if in assembly, wiring and operating the following basic rules are observed and adhered to:
• Use only shielded signal lines with a minimum diameter of 0.15 mm²
• To protect against electrical fields, connect the cable shield unilaterally, low resistance and
Low inductive with the operating lightning protection.
• Unused arteries in signal lines should be isolated from each other separately
• isolate signal and power lines separately in long parallel lines (a distance of 300 mm is respected )
Therefore, should never be different voltage levels, e.g. 230V/50 Hz power supply and measuring
Signal 24V DC in one cable together
• low the emission by the Installation of filter networks in plants with frequency. In the operating
Instructions of the manufacturer FU find the appropriate instructions.
• Wireless phones and Walky-talkies should never be used in the immediate vicinity of electronic
Devices