Technical data
Table Of Contents
- General Information
- Safety
- 3. Transport and Storage
- Product Features
- Technical Data
- Configuration and Functions
- 6.1. Elements
- 6.2. Menu, sections and parameters
- Machine setting
- If the same analog measuring system which is used for the angle also used for the angle Cutting length, then it is necessary, set the values for the cutting length calculation.
- Setting values with minimum angle: Place the cursor in the first row and first column of the table (line: min; column: S. Beg). Now, enter the smallest possible cut angle. Let down the cutting blade to beginning of the cut (till the point, where the upper beam and lower beam of the scissors just touch) and press the F2 key. Now place the cursor on the field in the first row and second column (row: Min; column: S. End) and let down the cutting blade to the end of the cut. Now press the F2 key again. Thus the values for the minimum angle are set up.
- Setting values with maximum angle:
- Place the cursor in the second row and second column of the table (line: max; column: S. Beg). Now, enter the biggest possible cut angle. Let down the cutting blade to beginning of the cut (till the point, where the upper beam and lower beam of the scissors just touch) and press the F2 key. Now place the cursor on the field in the first row and second column (row: Max; column: S. End) and let down the cutting blade to the end of the cut. Now press the F2 key again. Thus the values for the maximum angle are set up.Configuration of inputs and outputs
- 7. Operation
- 8. Interferences
- Maintenance
- Type Designation
- Accessories

Type Designation
-45-
10 Type Designation
P40 – XXX – 024 – XX – XX - XXXX
Positioning controller
Single axis with program memory
Construction
000 = standard
001 = special version
…
Supply voltage
024 = 24 VDC (+/- 20%)
Encoder inputs
X = Not equipped
0 = A, B (PNP) 24 VDC supply voltage for encoders/24 VDC – 20 KHz
1 = A, B, 0 (PNP) 24 VDC supply voltage for encoders/24 VDC – 20 KHz
2 = A,/A, B, /B (TTL) 24 VDC supply voltage for encoders 5 V-TTL – 100 KHz
3 = A, /A, B, /B, 0, /0 (TTL) 24 VDC supply voltage for encoders 5 V-TTL – 100 KHz
4 = one analog Input (only for 2
nd
axis)
5 = two analog Inputs (only for 2
nd
axis)
Outputs
X = Not equipped
0 = Digital Outputs (PNP)
1 = Analog output +/- 10V (PID regulated) - not possible with analog measurement system!
2 = Analog output 0… 10V (on request)
Options
X = Not equipped
C = Clamps
S = Serial interface RS232
EN = input NPN (including index pulse)
For exmaple:
P40 – Application Metal Shears with 24 VDC supply, 1 input with A, B, Z signal and two analog inputs, for
first axis analog output +/- 10V (PID regulated) for the second axis transistor outputs, connection with screw
clamps and RS232 interface:
P40 - 002 - 024 - 15 - 10 – CSXX