Installation Sheet

10
5 Push the right end of the motor mounting plate up and
snap it into the spring tab.
NOTE: The spring tab should be outside the slot in the
mounting plate.
A
B
A. Motor mounting plate
B. Spring clip
6 Align mounting holes and install 6 x 16 mm screws and
6.4 mm lock washers
B
A
A. Screw with lock washer
B. Mounting hole
7 Attach power supply connector from the range hood to
the connector on the blower motor assembly wiring box.
A
B
A. 4- 4x8 mm mounting screws
B. Security screws
Electrical connection
I WARNING
ELECTRICAL SHOCK HAZARD.
DISCONNECT POWER BEFORE SERVICING.REPLACE ALL
PARTS AND PANELS BEFORE OPERATING. FAILURE TO DO
SO CAN RESULT IN DEATH OR ELECTRICAL SHOCK.
• Remove the knockout and the Junction box cover and
install the conduit connector (cULus listed) in junction box.
A
E
B
F
C
D
A. White wires
B. Black wires
C. UL listed wire connector
D. Green (or bare) and yellow-green
ground wire
E. Home power supply cable
F. UL listed or CSA approved ½” strain relief
• Run 3 wires; black, white and green ,according to the
National Electrical Code and local codes and ordinances,
in
1
2” conduit from service panel to junction box.
I WARNING
ELECTRICALLY GROUND BLOWER. CONNECT GROUND WIRE
TO GREEN AND YELLOW GROUND WIRE IN TERMINAL BOX.
FAILURE TO DO SO CAN RESULT IN DEATH OR ELECTRICAL
SHOCK.
• Connect black wire from service panel to black or red in
junction box, white to white and green to green-yellow.
• Close and secure junction box cover.
Complete installation
Replace filters and check operation of the hood.
If range hood does not operate:
• Check that the circuit breaker is not tripped or the house
fuse blown.
• Disconnect power supply. Check that wiring is correct.
To get the most ecient use from your new range hood, read
the “Maintenance” section.
Keep your Installation Instructions and Use and Care Guide
close to range hood for easy reference.